18-CE09D1-1E-EN
47
Combustion Air Conversions
Important:
After deciding the orientation of the flue outlet, cut the
metal tabs around the appropriate 5” metal cutout on the
furnace cabinet and remove the cutout, if necessary.
Note:
When rotating the inducer it may be necessary to cut the wire
tie. A new wire tie must be installed once the inducer is rotated.
Note:
Self-tapping screws are recommended for attaching the vent
pipe to the inducer outlet.
Pressure Switch locations
S8B1: PS is connected to the hot header. Disregard pressure switch
tubing connected to the inducer. Not applicable on single stage
furnaces.
Upflow orientation with top venting
No changes need to be made to the inducer when installing the
furnace in upflow position when vented through the top.
Note:
Self-tapping screws are recommended for attaching the vent
pipe to the inducer outlet.
Upflow orientation with left side venting
Before proceeding, lay unit on its back to make the conversion easier.
The following changes need to be made to the inducer when installing
the furnace in upflow position with the combustion air vented out the
left side.
Note:
When rotating the inducer it may be necessary to cut the wire
tie. A new wire tie must be installed once the inducer is rotated.
1.
Remove the four screws holding the inducer in place.
2.
Rotate the inducer so the inducer outlet is pointing towards the 5”
cutout.
3.
Secure the inducer in place using the screws removed in step 1.
4.
Attach the vent to the inducer outlet.
Note:
Self-tapping screws are recommended for attaching the vent
pipe to the inducer outlet.
Upflow orientation with right side venting
Before proceeding, lay unit on its back to make the conversion easier.
The following changes need to be made to the inducer when installing
the furnace in upflow position with the combustion air vented out the
left side.
1.
Remove the four screws holding the inducer in place.
2.
Rotate the inducer so the inducer outlet is pointing towards the 5”
cutout.
3.
Secure the inducer in place using the screws removed in step 1.
4.
Attach the vent to the inducer outlet.
Note:
Self-tapping screws are recommended for attaching the vent
pipe to the inducer outlet.
Summary of Contents for S8B1A026M2PSAB
Page 12: ...12 18 CE09D1 1E EN Outline Drawings Table 2 14 5 Width Cabinet ...
Page 13: ...18 CE09D1 1E EN 13 Table 3 17 5 Width Cabinet O Ou ut tl li in ne e D Dr ra aw wi in ng gs s ...
Page 14: ...14 18 CE09D1 1E EN Table 4 21 Width Cabinet O Ou ut tl li in ne e D Dr ra aw wi in ng gs s ...
Page 15: ...18 CE09D1 1E EN 15 Table 5 24 5 Width Cabinet O Ou ut tl li in ne e D Dr ra aw wi in ng gs s ...
Page 57: ...18 CE09D1 1E EN 57 N No ot te es s ...
Page 58: ...58 18 CE09D1 1E EN N No ot te es s ...