STEP 7- Put control assembly in electrical box and fasten it 
with two screws provided with the kit.

STEP 8-  See wiring diagram for wiring connections (Figure 5).

Figure 4

Figure 5

Figure 6

Figure 7

Note

:The high voltage power supply must agree with the equip

ment nameplate.

Power wiring must comply with National, State and Local Codes.

Follow instructions on unit wiring diagram located on the inside of
the access panel.

Field Installed
Insulation Sheath
CC: Compressor Contactor
DFC: Defrost Control
OFM: Outdoor Fan Motor

Field Installed need to use wire to connections.

Reversing valve is energized in the Heating mode.

For the Heat Pump Select Jumper setting, please refer to ICM325HN Application Guide.

Connect the ground wire:Low Ambient Control Box to Outdoor Unit Control Box.

Outdoor Fan Motor

Outdoor Fan Motor

- Remove the fan black wire from the Deferost Control Board

.

- Connect the white wire of ICM325-HN to CN8.

- Cut the black terminal of the Outdoor Fan Motor.

Defrost 
Control Board

3

Mounting control assembly

Heat Pump

Select Jumper

Default Position

ICM325-HN

White

Insulation sheath

Black Insulation sheath

Outdoor Unit

Control Box

Low Ambient

Control Box