![Trane NEXIA XR724 User'S Manual And Installation Instructions Download Page 8](http://html1.mh-extra.com/html/trane/nexia-xr724/nexia-xr724_users-manual-and-installation-instructions_1150399008.webp)
8
18-HD82D1-1B-EN
SERVICE
continued
ABOUT
REMINDERS
Setting
Range
Description
Filtration Enable
[No], Yes
Filter change reminder
Filter Period*
[Monthly], Quarterly, Bi-Annually,
Annually
Filter change reminder period
Start Month*
[Jan], Feb, Mar, Apr, May, Jun,
Jul, Aug, Sep, Oct, Nov, Dec
Period start month
System Maint Enable
[No], Yes
System Maintenance reminder
Maint Period*
[Bi-Annually], Annually
Maintenance reminder period
First Maint Month*
Jan, Feb, [Mar], Apr, May, Jun,
Jul, Aug, Sep, Oct, Nov, Dec
Period start month
Second Maint Month*
Jan, Feb, Mar, Apr, May, Jun, Jul,
Aug, [Sep], Oct, Nov, Dec
2nd period start month
Humidifier Enable
[Yes], No
Start Month
[Jan], Feb, Mar, Apr, May, Jun,
Jul, Aug, Sep, Oct, Nov, Dec
Once all selections have been made, press the
Done button to exit and return to menu. Press Next to navigate to the next setting.
Setting
Range
Description
Version
XXXXXX
Firmware version number
Device ID (SIN)
XXXXXX
Unit serial number
ODU Type
None, AC, HP
Outdoor unit type setting
IDU Type
Electric, Gas/Oil, Hydronic
Indoor unit type setting
SOV
W/Cool, W/Heat
Switchover value type setting (HP only)
Once all selections have been made, press the
Done button to exit and return to menu. Press Next to navigate to the next setting.
RESTORE DEFAULTS
Setting
Action
Description
Restore HVAC Defaults
Yes, No
Resets all HVAC settings to Default Settings
Restore Factory Defaults
Press and Hold “
Yes
”
Press and hold “
Yes
” button until “Factory” is displayed
Resets HVAC and WiFi defaults
The following is a guide of the menu options available on screen accessed by pressing the Menu button. Certain
menu selections, which are marked by an asterisk ( * ), may or may not be present depending on other menu settings.
TEST MODE (stays on for 30 minutes)
Test Mode
Settings
Description
Blower (Non-VS)
Blower On
Energize “G” circuit
Blower (VS)
50%, 100%
Energize “G” and “BK” circuit
Cooling
Single Stage, 1st Stage, 2nd Stage Energize selected “Y1” or “Y2”, “O” and “G” circuit (BK also for VS
indoor unit)
Comp Heating*
Single Stage, 1st Stage, 2nd Stage
Energize selected “Y1” or “Y2” and “G” circuit (“BK” also for VS
indoor unit)
Indoor Heating
Single Stage, 1st Stage, 2nd Stage
Energize selected “W1” or “W2” (“G” circuit also for electric heat)
Aux Relay
Relay On
Close normally open dry contacts
Once testing is complete, press the
Done button to exit and return to menu.
XR724 USER GUIDE
Summary of Contents for NEXIA XR724
Page 12: ...12 18 HD82D1 1B EN XR724 NEXIA Enrollment continued XR724 USER GUIDE...
Page 14: ...14 18 HD82D1 1B EN XR724 Nexia WiFi Reconfiguration continued XR724 USER GUIDE...
Page 15: ...15 18 HD82D1 1B EN XR724 Nexia WiFi Reconfiguration continued XR724 USER GUIDE...
Page 16: ...16 18 HD82D1 1B EN XR724 Nexia WiFi Reconfiguration continued XR724 USER GUIDE...
Page 17: ...17 18 HD82D1 1B EN XR724 Nexia WiFi Reconfiguration continued XR724 USER GUIDE...