Trane KIT 16724 Installer'S Manual Download Page 2

6200 Troup Highway
Tyler, TX 75707
www.trane.com
www.americanstandardair.com

Procedure: 

  

1.  Remove valve cover, control box 

cover, and access panel.

2.  Using the blue wire supplied with the 

kit and the existing wire nut, fasten 
the stripped end of the blue wire 
to the unit’s low voltage common 
connection (B) at the low voltage 
common thermostat wire connection.  
See Figure 1.

3.  Route the ring terminal end of the 

blue wire along the same path as the 
other low voltage wires entering into 
the unit control box.

4.  Using the screw supplied with the kit, 

fasten the ring terminal end of the 
blue wire to the control box utilizing 
one of the screw starting dimples in 
the control box.  See Figure 2.

5.  The ring terminal connection should 

be a minimum of 1/4” from any other 
electrical connection or terminal in 
the box.

6.  Install all covers and panel.

Figure 2

Figure 1

Heat Pump

Neatly bundle all low voltage 

wires behind the service valve 

cover as shown.

Yellow/Red

Field wiring

Yellow

Blue

Black

(X2)

Red

Orange

B - Blue
Y1 - Yellow
Y2 - Brown

R - Red

O - Orange

W1 - White

Blue Wire 

Supplied 

with Kit

 

2 18-HH28D1-3

Attached 
Ring 
Terminal

See Figure 1 for Field Connections