Trane HUMD200A Safety Instructions And Installation Template Download Page 2

READ COMPLETE SAFETY INSTRUCTIONS AND INSTALLATION TEMPLATE BEFORE STARTING

TEMPLATE MUST BE LEVEL

– TOP –

READ REVERSE SIDE FIRST!

READ REVERSE SIDE FIRST!

IMPORTANT!

Be sure User’s Information Guide

containing instructions for operation and warranty information is
given to owner in order to avoid unnecessary calls. Warranty is
void unless humidifier is installed by qualified heating and air
conditioning contractor due to possible misapplication of product.

1.

Remove front cover by pressing center

tabs on top and bottom of the cover (1) and
base (2). Pull feed tube (3) out of the water
distribution tray (4). Tip the evaporative
assembly forward and lift it out 
of the humidifier. 

(See Figure 1)

2.

The humidifier comes assembled for left

side discharge. If converting to right side
discharge, the base can be rotated so round
collar is facing to the right. 

S

wap the location

of the hole plug (10) and drain spud (9) if using
a right side discharge. To remove the cap,
push and twist from inside the housing while
lifting the cap up slightly on the outside. To
remove the drain spud, twist and push from 
the outside of the base.

3.

Using a level, position this template at

least 3 inches above the furnace housing or
cooling coil, if applicable, for clearance of
the drain line. Trace around template edges.
Remove the template and accurately cut the
plenum opening 9

1

2

” x 9

1

2

”, 

being careful 

to avoid injury from sharp edges.

4.

Place the humidifier into the plenum

opening, install six sheet metal mounting
screws (not furnished) at the top and sides 
of the humidifier interior.

5.

Install a 6” collar in a convenient location

on the opposite plenum. Attach a 90° elbow
and measure the length of 6” round duct
required to make the connection. The design
of the humidifier collar provides a solid
connection with the bypass duct through the
use of inside support ribs and pre-formed
holes for sheet metal screws. 

S

lip the duct

inside the collar of the humidifier, up to the
support ribs. Using the pre-formed holes at
the top and bottom of the humidifier collar,
secure the duct to the humidifier collar with
two sheet metal mounting screws (not
furnished). 

S

upport bypass ducts longer than

4 feet to prevent sagging.

6.

Reinstall the evaporative assembly back

into the base, with the bottom of the scale
control insert (6) sitting firmly in the inside of
the drain spud (9). Push the feed tube back
into the water distribution tray. 

(See Figure

2)

Put the front cover back on. If the

nameplate (11) is upside down, remove it
and rotate the nameplate so it is right side
up, and snap back into place. Turn damper
handle (8) to the open position “WINTER” for
the heating season, or closed position

S

U

MM

ER” for the cooling season.

7.

Locate and install the 

M

anual Humidifier

C

ontrol by following the instructions shown in

step #7A. 

DISCONNECT ELECTRICAL POWER

TO FURNACE BEFORE PROCEEDING TO 
STEP #7A!

LOCATION

1. Locate on inside wall of living area

approximately 5 feet above floor, or
in the furnace return air plenum or
duct. Adapter Plate Part No.
BAYPLT01A

M

H

C

OA is required for

return installation. If humidifier is
mounted on return, Humidifier

C

ontrol must be at least 6” upstream

of humidifier.

2. Do not locate 

C

ontrol in the direct

path of furnace discharge air or
drafts from open doors and windows.

3. Do not install where operation might

be affected by lamps, sunlight,
fireplace registers, radiators,
concealed air ducts and pipes, or
room occupants.

4. The basic rules for location of

thermostats also apply to humidifier
controls.

8.

C

onnect the transformer 120 VA

C

 primary

wires to the integrated Furnace 

C

ontrol

Accessory Terminals. The terminals are
marked HU

M

-H, HU

M

-N, where available. The

HU

M

 terminals will provide 120 VA

C

 to the

transformer whenever there is a call for heat.
The transformer is designed to be mounted on
a junction box. 

S

ee furnace Installer’s Guide

for wiring recommendations. 

NOTE: For gas

furnaces without humidifier accessory
terminals providing 120 VAC, use the Current
Sensing Relay (BAYRLY10ASENSA).

9.

Tap into the top or side (not bottom) of the

water supply line with the saddle valve
furnished. 

S

ee instructions on saddle valve

package. The humidifier will function with

cold, hot, softened or unsoftened water. The
use of service hot water (140°F 

M

AX.) and

constant blower operation will provide
maximum evaporative capacity. 

NOTE: The saddle valve is designed to be
fully opened or closed. Do not use it to
regulate water flow.

10.

C

onnect tubing from the saddle valve

to the inlet side of the solenoid valve using

1

4

” O.D. copper tubing (not furnished).

DOUBLE WRENCH TO PREVENT LEAKING! 
(See Figure 3)

11.

Drain spud is designed to accept 

1

2

I.D. plastic hose (not furnished). Run drain
line from drain spud to floor drain.

CAUTION: If hose clamp is used, do not
over tighten, drain spud could crack. Be
sure drain line has continuous slope.
NOTE: Do not sweat or directly attach
metal drain line to fitting. Do not use
solvent type adhesive when connecting
plastic drain line, since damage to fitting
could result.

12.

Open saddle valve completely and turn

on furnace. Turn up Humidifier 

C

ontrol so

that humidifier will turn on. Allow humidifier
to run until water is observed coming out of
the drain line. 

C

heck to see if humidifier and

saddle valve are watertight. 

C

heck

operation to make sure that all electrical
components function properly. 

S

et

Humidifier 

C

ontrol to level recommended in

User’s Information Guide.

NOTE:

BEFORE LEAVING THE

JOB SITE, MAKE SURE:
1. Saddle valve is fully open.
2. All plumbing connections are

watertight.

3. Humidifier functions properly.
4. Bypass damper is in proper

position.

Figure 1

Figure 2

Figure 3

18-

C

H30D1-2

10006956   B2204061B   7.08

7A.

MANUAL HUMIDIFIER CONTROL INSTALLATION INSTRUCTIONS:

The 

M

anual Humidifier 

C

ontrol is designed for low voltage service to control

humidification equipment. An increase in relative humidity expands the nylon ribbon
which opens the control switch to stop operation of the humidifier. A decrease
in relative humidity reverses the process and closes the control switch.

GENERAL INSTRUCTIONS

1. 

Do not attempt to repair or
recalibrate Humidifier Control.
Humidifier Controls requiring 
service should be returned to 
your distributor.

2. Use humidifier control in low voltage

(24 VA

C

) applications only. Install 

24 VA

C

 wiring to humidifier control 

as shown in Wiring Diagram,
opposite side.

3. 

M

ake sure no bare wires are

exposed or insulation damaged.
Insulation on wire should extend 
to head of screws.

4. 

M

ake sure all splices are

mechanically and electrically secure.

5. To remove dirt or other foreign matter

from nylon ribbon and control interior,
dust lightly with a fine, soft brush.

90-1067

90-1068

90-1069

1. Front 

C

over

2. Base
3. Feed Tube
4. Water Distribution Tray
5. Humidifier Pad
6.

S

cale 

C

ontrol Insert

7. Integral Damper
8. Damper Handle
9. Drain 

S

pud

10. Hole Plug
11. Nameplate
12.

S

olenoid Valve

8

5

3

4

1

11

6

9

7

2

10

12

90-1108

FURNISHED ITEMS

ITEMS NOT FURNISHED

Built-in bypass damper

24 VA

C

 

M

anual Humidifier 

C

ontrol

24 VA

C

 Transformer

S

addle valve

Humidifier Installation Template

M

ounting screws (sheet metal screws)

Water supply line (

1

4

” copper)

Drain line (

1

2

” I.D. hose) 

Low voltage wire

Bypass ductwork

M

anual Humidifier 

C

ontrol Adapter Plate

BAYPLT01A

M

H

C

OA

C

urrent 

S

ensing Relay 

BAYRLY10A

S

EN

S

A (if required)