Introduction

Warnings, Cautions, and Notices

Safety advisories appear throughout this manual as required. Your personal safety and the proper 
operation of this machine depend upon the strict observance of these precautions.

The three types of advisories are defined as follows:

WARNING

Indicates a potentially hazardous situation which, if not avoided, could result in 

death or serious injury.

CAUTION

s

Indicates a potentially hazardous situation which, if not avoided, could result in 

minor or moderate injury. It could also be used to alert against unsafe practices.

NOTICE

Indicates a situation that could result in equipment or property-damage only 

accidents.

WARNING

Proper Field Wiring and Grounding Required!

Failure to follow code could result in death or serious injury. All field wiring MUST be 
performed by qualified personnel. Improperly installed and grounded field wiring poses FIRE 
and ELECTROCUTION hazards. To avoid these hazards, you MUST follow requirements for field 
wiring installation and grounding as described in NEC and your local/state electrical codes. 
Failure to follow code could result in death or serious injury. 

WARNING

Hazardous Voltage w/Capacitors!

Failure to disconnect power and discharge capacitors before servicing could result in death or 
serious injury. Disconnect all electric power, including remote disconnects and discharge all 
motor start/run capacitors before servicing. Follow proper lockout/tagout procedures to 
ensure the power cannot be inadvertently energized. For variable frequency drives or other 
energy storing components provided by Trane or others, refer to the appropriate 
manufacturer’s literature for allowable waiting periods for discharge of capacitors. Verify with 
an appropriate voltmeter that all capacitors have discharged.

For additional information regarding the safe discharge of capacitors, see PROD-SVB06A-EN.

Summary of Contents for BAYSENS050m

Page 1: ... equipment The installation starting up and servicing of heating ventilating and air conditioning equipment can be hazardous and requires specific knowledge and training Improperly installed adjusted or altered equipment by an unqualified person could result in death or serious injury When working on the equipment observe all precautions in the literature and on the tags stickers and labels that a...

Page 2: ...d personnel Improperly installed and grounded field wiring poses FIRE and ELECTROCUTION hazards To avoid these hazards you MUST follow requirements for field wiring installation and grounding as described in NEC and your local state electrical codes Failure to follow code could result in death or serious injury WARNING Hazardous Voltage w Capacitors Failure to disconnect power and discharge capaci...

Page 3: ...irements for arc flash protection PRIOR to servicing the unit NEVER PERFORM ANY SWITCHING DISCONNECTING OR VOLTAGE TESTING WITHOUT PROPER ELECTRICAL PPE AND ARC FLASH CLOTHING ENSURE ELECTRICAL METERS AND EQUIPMENT ARE PROPERLY RATED FOR INTENDED VOLTAGE WARNING Follow EHS Policies Failure to follow instructions below could result in death or serious injury All Trane personnel must follow the comp...

Page 4: ...troduction InstallationKit The installation kit includes the following Wireless Receiver Wireless Zone Sensor Wire Harness Mounting Bracket Two 8 32 x Pan Head Screws Two 6 32 x Pan Head Screws Two 10 32 x Pan Head Screws ...

Page 5: ...t holes in the right hand back corner of the control box floor Use the two 8 32 x 1 2 screws to mount the bracket to the Odyssey control box See Figure 3 10 12 ton split system units If the control box does not have pre drilled holes to mount the bracket using a 29 drill Diameter 0 136 hole drill two engagement holes in the front edge of the control box floor Use the two 8 32 x 1 2 screws to mount...

Page 6: ...Figure 2 3 10 Ton Packaged Rooftop Units Figure 3 6 7 Ton Split System Units 6 ACC SVN129D EN Installation ...

Page 7: ...Figure 4 10 12 Ton Split System Units Figure 5 15 25 Ton Split System Units ACC SVN129D EN 7 Installation ...

Page 8: ...Table 1 Table 1 Wire Label RTRM J6 Termination ZONE J6 1 GND SIGNAL J6 2 SETPOINT J6 3 FAN SYSTEM J6 4 HEAT SETPOINT J6 5 24 VAC DC J6 14 GND POWER J6 6 9 Check all connections Once connections are verified correct reapply power to the unit and UCM 10 Refer to the Wireless Sensor Installation Operation and Maintenance BAS SVX04 EN document to associate the receiver with the Wireless Display Sensor...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...cations without notice We are committed to using environmentally conscious print practices Trane and American Standard create comfortable energy efficient indoor environments for commercial and residential applications For more information please visit trane com or americanstandardair com ACC SVN129D EN 05 Jun 2020 Supersedes ACC SVN129C EN Jan 2015 ...

Reviews: