18-AH47D1-2
5
Figure 6 - Connecting liquid line
Figure 5 - Installing TEV
3) Bolt the TEV (which was removed from the
original coil) to the distributor assembly. (See
Figure 5)
Note: Torque specification for TEV equals 1/6
turn past finger tight.
4) Connect the liquid line from the removed coil
to the TEV by bolting it to the refrigerant enter-
ing connection of the TEV. (See Figure 6)
5) The liquid line must be wrapped to prevent
copper tubing from coming in contact with alu-
minum tubing and the outer sheet metal cover.
(See Figure 7)
Note: NON-metallic tape such as electrical
tape, foam tape, armaflex etc. is recommended.
Figure 7 - Wrapping liquid line