Functional Unit Parts

Residential Humidifier Units

HUMD-UP-1D-EN

Models

AHUMD200A**00BA

AHUMD300A**00BA

AHUMD500A**00BA

EHUMD200A**00BA

EHUMD300A**00BA

EHUMD500A**00BA

THUMD200A**00BA

THUMD300A**00BA

THUMD500A**00BA

Mnemonic

Part No.

Description

Qty.

Fan-Powered

HUM with

Relay

Fan-Powered

HUM with

Circuit Board

BLD01036

BLADE; FAN, LFP, 

*HUMD500

1

BRD03067

BOARD; CIRCUIT, LFP, 

*HUMD500

1

CNT04841

CONTROL; CONVERTIBLE AUTOMATIC HUMIDIFIER, 
AMER. STD., LBP/LFP, 

AHUMD300, 500

1

CNT04842

CONTROL; CONVERTIBLE AUTOMATIC HUMIDIFIER, 
TRANE, LBP/LFP, 

THUMD300, 500

1

GRM00883

GROMMET; ACCOMMODATES .099 –.144 PANEL THICK-
NESS

1

MOT11925

MOTOR; LFP, 

*HUMD500

1

ORF01440

ORIFICE; YELLOW, LBP/SBP, 

*HUMD200, 300

1

ORF01441

ORIFICE; BLUE, POWER UNITS, 

*HUMD500

1

RLY02948

RELAY; MODEL 50

1

SEN01259

SENSOR; OUTDOOR WITH ATTACHED BRACKET, AHC, 
OEM, LBP/LFP, 

*HUMD300, *HUMD500

1

SWT02795

SWITCH; DISCONNECT FEMALE, LFP, 

*HUMD500

1

SWT03081

SWITCH; DISCONNECT MALE, LFP, 

*HUMD500

1

THT02444

THERMOSTAT; HUMIDISTAT, MANUAL, TRANE, SBP, 

*HUMD200

1

THT02445

THERMOSTAT; HUMIDISTAT, MANUAL, AM STD, SBP, 

*HUMD200

1

TRR01901

TRANSFORMER; SBP, LBP,

 *HUMD200, *HUMD300

1

VAL08192

VALVE; SADDLE, SBP, LBP, LFP

1

VAL08193

VALVE; SOLENOID, 24VAC, SBP, LBP, 

*HUMD200, 

*HUMD300

1

VAL08194

VALVE; SOLENOID, 24VAC, LFP, 

*HUMD500

1

5462

POWER CORD

1

5463

POWER CORD

1

5464

MOTOR

1

5465

FEMALE DISCONNECT

1

5466

INTERNAL RELAY

1

About Trane and American Standard Heating and Air Conditioning

Trane and American Standard create comfortable, energy efficient indoor environments for residential applications.

For more information, please visit www.trane.com or www.americanstandardair.com

The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are 

committed to using environmentally conscious print practices.

© 2020

HUMD-UP-1D-EN   05 Aug 2020  
Supersedes HUMD-UP-1C   (August 2018)

Summary of Contents for AHUMD200A 00BA Series

Page 1: ...NNECTS BEFORE SERVICING FOLLOW PROPER LOCKOUT TAGOUT PROCEDURES TO ENSURE THE POWER CAN NOT BE INADVERTENTLY ENERGIZED FAILURE TO DISCONNECT POWER BEFORE SERVICING COULD RESULT IN DEATH OR SERIOUS INJURY EHUMD500A HUMIDIFIER INSTALLATION WITH COMMUNICATING SYSTEM AIR HANDLER Diagram A AS NEEDED FOR EHUMD500 WITH COMMUNICATING AIR HANDLER Included humidity control and outdoor sensor not required Ci...

Page 2: ...FORMER Furnished 24VAC EHUMD500A HUMIDIFIER INSTALLATION WITH COMMUNICATING SYSTEM FURNACE EHUMD500A HUMIDIFIER INSTALLATION WITH NON COMMUNICATING SYSTEM AIR HANDLER EHUMD500A HUMIDIFIER INSTALLATION WITH NON COMMUNICATING SYSTEM AIR HANDLER 24V ODT H C R 24VAC 120VAC BR BR Wire Nuts 1 4 inch Female Quick Connects Note Insulated Terminals are recommended 18 AWG 2 Conductor Wire Note Verify that s...

Page 3: ...print practices 2020 18 HE87D1 4A EN 05 Aug 2020 Supersedes 18 HE87D1 4 August 2018 Notes Enable HUM Control through the CONT900 Installer Setup Menu ISU0372 Option 1 RH Setpoint Option 2 Dewpoint Control See advanced features in CONT900 Installer s Guide for operating details BYPASS HUMIDIFIER 18 AWG 2 Conductor Wire Diagram C FOR EHUMD300AB EHUM200AB WITH 120VAC OUTPUT TERMINALS BYPASS HUMIDIFIE...

Page 4: ... SWT02795 SWITCH DISCONNECT FEMALE LFP HUMD500 1 SWT03081 SWITCH DISCONNECT MALE LFP HUMD500 1 THT02444 THERMOSTAT HUMIDISTAT MANUAL TRANE SBP HUMD200 1 THT02445 THERMOSTAT HUMIDISTAT MANUAL AM STD SBP HUMD200 1 TRR01901 TRANSFORMER SBP LBP HUMD200 HUMD300 1 VAL08192 VALVE SADDLE SBP LBP LFP 1 VAL08193 VALVE SOLENOID 24VAC SBP LBP HUMD200 HUMD300 1 VAL08194 VALVE SOLENOID 24VAC LFP HUMD500 1 5462 ...

Reviews: