HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING
WARNING:
IMPORTANT — This document contains a wiring diagram, a parts list, and service information. This is customer property
and is to remain with this unit. Please return to service information pack upon completion of work.
Service Facts
4TWR2036-SF-1
Split System
Heat Pump
4TWR2036A1000AA
E - SPLIT HEA
T
PUMP
Page E-757-000
P.I. 10/01
© 2001 American Standard Inc. All Rights Reserved
NOTICE: Since The Trane Company has a policy of continuous product and product data improvement,
it reserves the right to change design and specifications without notice.
▲
CAUTION
!
UNIT CONTAINS R-410A REFRIGERANT!
R-410A OPERATING PRESSURE EXCEEDS THE
LIMIT OF R-22. PROPER SERVICE EQUIPMENT IS
REQUIRED. FAILURE TO USE PROPER SERVICE
TOOLS MAY RESULT IN EQUIPMENT DAMAGE OR
PERSONAL INJURY.
SERVICE
USE ONLY R-410A REFRIGERANT AND
APPROVED POE COMPRESSOR OIL.
PRODUCT SPECIFICATIONS
OUTDOOR UNIT
12
4TWR2036A1000AA
POWER CONNS. — V/PH/HZ
3
208/230/1/60
MIN. BRCH. CIR. AMPACITY
21
BR. CIR.
MAX. (AMPS)
35
PROT. RTG.
}
MIN. (AMPS)
30
COMPRESSOR
CLIMATUFF
®
- SCROLL
NO. USED - NO. SPEEDS
1 - 1
VOLTS/PH/HZ
208/230/1/60
R.L. AMPS
7
- L.R. AMPS
15.4 - 83
FACTORY INSTALLED
START COMPONENTS
8
NO
INSULATION/SOUND BLANKET
YES
COMPRESSOR HEAT
NO
OUTDOOR FAN
PROPELLER
DIA. (IN.) - NO. USED
23 - 1
TYPE DRIVE - NO. SPEEDS
DIRECT - 1
CFM @ 0.0 IN. W.G.
4
3300
NO. MOTORS - HP
1 - 1/6
MOTOR SPEED R.P.M.
825
VOLTS/PH/HZ
200/230/1/60
F.L. AMPS
1.4
OUTDOOR COIL — TYPE
SPINE FIN™
ROWS - F.P.I.
1 - 24
FACE AREA (SQ. FT.)
23.70
TUBE SIZE (IN.)
5/16
REFRIGERANT CONTROL
EXPANSION VALVE
REFRIGERANT
LBS. — R-410A (O.D. UNIT)
5
6 LBS. - 8 OZ.
FACTORY SUPPLIED
YES
LINE SIZE - IN. O.D. GAS
6
3/4
LINE SIZE - IN. O.D. LIQ.
6
3/8
FCCV
RESTRICTOR ORIFICE SIZE
.063
DIMENSIONS
H X W X D
CRATED (IN.)
46 x 30.1 x 33.8
WEIGHT
SHIPPING (LBS.)
257
NET (LBS.)
227
1
Certified in accordance with the Air-Source Unitary Heat Pump Equipment
certification program, which is based on A.R.I. standard 210/240.
2
Rated in accordance with A.R.I. standard 270.
3
Calculated in accordance with Natl. Elec. Codes. Only use HACR circuit breakers
or fuses.
4
Standard Air -- Dry Coil -- Outdoor
5
This value approximate. For more precise value see unit nameplate.
6
Max. linear length 60 ft.; Max. lift - Suction 60 ft.; Max lift - Liquid 60 ft.
For greater length consult refrigerant piping software Pub. No. 32-3312-01.
7
This value shown for compressor RLA on the unit nameplate and on this
specification sheet is used to compute minimum branch circuit ampacity and
max. fuse size. The value shown is the branch circuit selection current.
8
No means no start components. Yes means quick start kit components.
PTC means positive temperature coefficient starter.
TUBING INFORMATION
Tubing Sizes
Tubing
Additional
Suction
Liquid
Length
Refrigerant
Tubing lengths in excess of sixty (60) feet see application software.
20'
30'
40'
50'
60'
3/4"
3/4"
3/4"
3/4"
3/4"
3/8"
3/8"
3/8"
3/8"
3/8"
3 oz.
9 oz.
15 oz.
21 oz.
27 oz.
CONTAINS REFRIGERANT!
SYSTEM CONTAINS OIL AND REFRIGERANT UNDER
HIGH PRESSURE. RECOVER REFRIGERANT TO RELIEVE
PRESSURE BEFORE OPENING SYSTEM.
Failure to follow proper procedures can result in personal
illness or injury or severe equipment damage.
▲
CAUTION
!
▲
WARNING
!
THIS INFORMATION IS INTENDED FOR USE BY INDIVIDUALS POSSES-
SING ADEQUATE BACKGROUNDS OF ELECTRICAL AND MECHANICAL
EXPERIENCE. ANY ATTEMPT TO REPAIR A CENTRAL AIR CONDITION-
ING PRODUCT MAY RESULT IN PERSONAL INJURY AND OR
PROPERTY DAMAGE. THE MANUFACTURER OR SELLER CANNOT BE
RESPONSIBLE FOR THE INTERPRETATION OF THIS INFORMATION,
NOR CAN IT ASSUME ANY LIABILITY IN CONNECTION WITH ITS USE.
▲
CAUTION
!
RECONNECT ALL GROUNDING DEVICES.
ALL PARTS OF THIS PRODUCT CAPABLE OF CONDUCTING
ELECTRICAL CURRENT ARE GROUNDED. IF GROUNDING
WIRES, SCREWS, STRAPS, CLIPS, NUTS OR WASHERS
USED TO COMPLETE A PATH TO GROUND ARE REMOVED
FOR SERVICE, THEY MUST BE RETURNED TO THEIR
ORIGINAL POSITION AND PROPERLY FASTENED.
HOT SURFACE!
DO NOT TOUCH TOP OF COMPRESSOR.
May cause minor to severe burning.
▲
CAUTION
!