Trane 4TVS0007DF000A Technical & Service Manual Download Page 3

Floor standing indoor unit with DC fan motor

2

1. Feature

1.1 Exposed & Concealed type

Concealed type

1.2 Adopting DC fan motor

Efficiency can be up to 90%. Contrast with the AC fan motor, the power consumption of DC fan motor can

reduce up to 30%.

1.3 Lower noise

Flat shape air outlet, three speeds adjustment. Smoother airflow with less turbulence.

Adoption of the built-in Fujikoki brand electronica expansion valve, ensures precise flow control, as well as

lower modulation noise when EXV operating.

1.4 Easy Installation

Floor standing types can be hung on the wall or installed on the floor. The former can make cleaning and

maintenance much more easily. Running the piping from the back allows the unit to be hung on walls.

Cleaning under the unit, where dust tends to accumulate, is considerably easier.

1.5 Easy maintenance

Filter is equipped as standard accessory; and it can be removed and cleaned easily due to Trane’s

sophisticated design as well as the removable blades.

Streamlined appearance makes it much more harmonious with the decoration. All metal parts are made of

commercial grade galvanized steel, providing maximum protection against corrosion.

1.6 Auto restart

When the indoor unit is powered off, it will auto restart when powered on again after 3 minutes and operate

in the original state.

DC and AC motors power contrast

Power Inpu t:W

Air Flow:CFM

200

0

50

100

150

200

300

400

500

600

800

1000

1200

DC moto r

AC moto r

Summary of Contents for 4TVS0007DF000A

Page 1: ...Technical Service Manual TVR LX Systems Floor standing indoor unit with DC Fan Motor 220 240V 50 60Hz 1ph July 2018...

Page 2: ...r 1 Floor standing indoor unit with DC fan motor 1 Feature 2 2 Specifications 3 3 Dimensions 6 4 Service Spaces 7 5 Piping Diagrams 8 6 Wiring Diagrams 9 7 Capacity Tables 12 8 Electrical Characterist...

Page 3: ...g and maintenance much more easily Running the piping from the back allows the unit to be hung on walls Cleaning under the unit where dust tends to accumulate is considerably easier 1 5 Easy maintenan...

Page 4: ...3 3 3 Indoor air flow H M L m3 h 530 456 400 569 485 421 624 522 375 Indoor noise level H M L dB A 36 33 29 36 33 29 37 34 30 Indoor unit Dimension W H D mm 840 545 212 840 545 212 1040 545 212 Packin...

Page 5: ...or air flow H M L m3 h 660 542 440 1150 970 830 Indoor noise level H M L dB A 37 34 30 41 35 31 Indoor unit Dimension W H D mm 1040 545 212 1340 545 212 Packing W H D mm 1139 639 305 1425 639 305 Net...

Page 6: ...ndoor air flow H M L m3 h 1380 1100 870 1380 1100 870 Indoor noise level H M L dB A 44 39 33 44 39 33 Indoor unit Dimension W H D mm 1340 545 212 1340 545 212 Packing W H D mm 1425 639 305 1425 639 30...

Page 7: ...ng MODEL A B C mm 4TVS0007DF000AA 6 4 12 7 725 4TVS0009DF000AA 4TVS0012DF000AA 6 4 12 7 925 4TVS0015DF000AA 4TVS0018DF000AA 9 5 15 9 1225 4TVS0024DF000AA 4TVS0027DF000AA Connecting point of refrigeran...

Page 8: ...and air delivery at the top for installation on a wall Required clearance for above 3 versions Additionally it is required to keep 20mm between the rear and wall 600mm between the front face and the o...

Page 9: ...Floor standing indoor unit with DC fan motor 8 5 Piping Diagrams flare nut flare nut T2B gas side motor heat exchanger fan EXV liquid side T2 T1...

Page 10: ...Floor standing indoor unit with DC fan motor 9 6 Wiring Diagrams...

Page 11: ...3 4500W 1 5HP 4 5600W 2 0HP 5 7100W 2 5HP 6 8000W 3 0HP Note Base on different purposes to setting the switch cords on PC panel of indoor electrical control box Once finish the setting please cut off...

Page 12: ...Floor standing indoor unit with DC fan motor 11 SW5 definition SW6 definition SW7 definition J1 J2 definition 0 1 definition...

Page 13: ...1 9 2 8 1 9 3 0 1 9 3 3 2 0 3 4 1 9 21 0 1 9 1 6 2 3 1 8 2 6 1 9 2 8 1 9 3 0 1 9 3 3 2 0 3 4 1 9 23 0 1 9 1 6 2 3 1 8 2 6 1 9 2 8 1 9 3 0 1 9 3 3 2 0 3 4 1 9 25 0 1 9 1 6 2 3 1 8 2 6 1 9 2 8 1 9 3 0 1...

Page 14: ...5 3 2 27 0 3 9 2 7 4 6 3 0 5 3 3 3 5 6 3 4 5 9 3 5 6 4 3 5 6 4 3 2 29 0 3 9 2 7 4 6 3 0 5 3 3 3 5 6 3 4 5 9 3 5 6 3 3 5 6 4 3 3 31 0 3 9 2 7 4 6 3 0 5 3 3 3 5 6 3 4 5 9 3 5 6 2 3 4 6 2 3 2 33 0 3 9 2...

Page 15: ...7 5 5 3 8 0 5 5 8 4 5 4 9 4 5 5 9 3 5 0 27 0 5 5 4 4 6 6 4 9 7 5 5 3 8 0 5 5 8 4 5 4 9 1 5 3 9 2 5 1 29 0 5 5 4 4 6 6 4 9 7 5 5 3 8 0 5 5 8 4 5 5 9 0 5 3 9 1 5 0 31 0 5 5 4 4 6 6 4 9 7 5 5 3 8 0 5 5 8...

Page 16: ...14 2 14 11 00 10 50 2 24 2 24 2 24 2 24 2 24 2 24 10 00 9 50 2 34 2 34 2 34 2 34 2 34 2 34 9 10 8 50 2 40 2 40 2 40 2 40 2 40 2 40 7 60 7 00 2 43 2 43 2 43 2 43 2 43 2 43 5 60 5 00 2 53 2 53 2 53 2 53...

Page 17: ...79 4 79 4 79 5 60 5 00 4 98 4 98 4 98 4 98 4 98 4 98 3 70 3 00 5 23 5 23 5 23 5 23 5 23 5 23 0 70 0 00 5 61 5 61 5 61 5 61 5 61 5 29 2 20 3 00 5 92 5 92 5 92 5 92 5 80 5 29 4 10 5 00 6 11 6 11 6 11 6...

Page 18: ...03 6 03 11 00 10 50 6 30 6 30 6 30 6 30 6 30 6 30 10 00 9 50 6 57 6 57 6 57 6 57 6 57 6 57 9 10 8 50 6 75 6 75 6 75 6 75 6 75 6 75 7 60 7 00 6 84 6 84 6 84 6 84 6 84 6 84 5 60 5 00 7 11 7 11 7 11 7 1...

Page 19: ...V 198 254 0 4 5 0 029 0 32 4TVS0012DF000AA 50 60 220 240V 198 254 0 33 5 0 022 0 26 4TVS0015DF000AA 50 60 220 240V 198 254 0 36 5 0 027 0 29 4TVS0018DF000AA 50 60 220 240V 198 254 0 61 5 0 049 0 49 4T...

Page 20: ...result of ambient conditions 2 Semi anechoic chamber conversion value measured at a point 1m in front of the unit at a height of 1 5m 9 2 Test value Model Sound test value dB A H M L 4TVS0007DF000AA...

Page 21: ...pressure level dB 0dB 0 0002 bar Audibility limits of continuous white sound Octave band center frequency Hz Sound pressure level dB 0dB 0 0002 bar Audibility lim its of continuous white sound Octave...

Page 22: ...tity Shape Usage Owner s manual 1 Installation manual 1 Pipe insulation material 2 Heat insulation Signal receiver display board 1 Receive signals Mounting screw ST3 9x12 C H 4 Cooper nut 1 Use for pi...

Reviews: