Service Facts

© Trane 2008

PRODUCT SPECIFICATIONS

MODEL

RATED VOLTS/PH/HZ.

RATINGS 

1

INDOOR COIL — Type

Rows — F.P.I.
Face Area (sq. ft.)
Tube Size (in.)
Refrigerant Control
Drain Conn. Size (in.)   

2

DUCT CONNECTIONS

INDOOR FAN — Type

Diameter-Width (In.)
No. Used
Drive - No. Speeds
CFM vs. in. w.g.
No. Motors — H.P.
Motor Speed R.P.M.
Volts/Ph/Hz
F.L. Amps

FILTER
Vertical Applications

Filter Furnished?
Type Recommended
No.-Size-Thickness

Horizontal Applications

Filter Furnished?
Recommended Size

REFRIGERANT

Ref. Line Connections
Coupling or Conn. Size — in. Gas
Coupling or Conn. Size — in. Liq.

DIMENSIONS

Crated (In.)
Uncrated

WEIGHT

Shipping (Lbs.) / Net (Lbs.)

TEE3C49A-SF-1B

Convertible Variable Speed –
Communicating Air Handlers

2/4TEE3C49A1000A

TEE3C49A-SF-1B

2/4TEE3C49A1000A

200-230/1/60

See O.D. Specifications

Plate Fin

4 — 14.0

6.19

3/8 - Copper

TXV - Non-Bleed 

4

3/4 NPT

See Outline Drawing 

5

Centrifugal

10 x 10

1

Direct - Serial ECM

See Fan Performance Table

1 — 3/4

Variable

200-230/1/60

6.8

Yes

Low Velocity

1 - 20 X 25 - 1 in.

See Note 

6

See Note 

3

  R-22           R-410A

Brazed         Brazed

1-1/8              7/8

 3/8                3/8

H x W x D

59-1/2 x 28-1/2 x 23-1/2

57-7/8 x 26 x 21

188 / 173

AIRFLOW ADJUSTMENT

If the airflow needs to be increased or decreased, see
the Airflow Label on the air handler or the Blower Per-
formance table in these Service Facts. Information on
changing the speed of the blower motor for your specific
outdoor model size is in the Blower Performance Table
or User Interface Menu.

Blower speed changes are made with the User Interface
Menu mounted in the control box.

CAUTION

!

RECONNECT ALL GROUNDING DEVICES.
All parts of this product that are capable of conducting
electrical current are grounded.  If grounding wires,
screws, straps, clips, nuts, or washers used to com-
plete a path to ground are removed for service, they
must be returned to their original position and prop-
erly fastened.

 

HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

WARNING:

IMPORTANT — This document contains a wiring diagram
and service information. This is customer property and is
to remain with this unit. Please return to service information
pack upon completion of work.

WARNING

!

THIS INFORMATION IS INTENDED FOR USE BY INDI-
VIDUALS POSSESSING ADEQUATE BACKGROUNDS
OF ELECTRICAL AND MECHANICAL EXPERIENCE.
ANY ATTEMPT TO REPAIR A CENTRAL AIR CONDI-
TIONING PRODUCT MAY RESULT IN PERSONAL IN-
JURY AND OR PROPERTY DAMAGE. The manufacturer
or seller cannot be responsible for the interpretation of
this information, nor can it assume any liability in con-
nection with its use.

1

These Air Handlers are A.R.I. certified with various Split System Air Condi-
tioners and Heat Pumps (ARI STANDARD 210/240).  Refer to the Split Sys-
tem Outdoor Unit Product Data Guides for performance data.

2

3/4" Male Plastic Pipe (Ref.:  ASTM 1785-76)

3

Minimum filter size for horizontal applications will be based on airflow selec-
tion and will be calculated as follows:
Low Velocity Filter:  Face area (Sq. Ft.)  =  CFM / 300
High Velocity Filter:  Face area (Sq. Ft.)  =  CFM / 500

Torque Spec for TXV = Tighten 1/6 turn past finger tight

See Installer's Guide for drawings

For customer ease of filter maintenance, it is recommended that a properly

sized, 

remote filter

 and grille be installed for horizontal applications.  Airflow

should not exceed the face value of the filter being used.  

The factory in-

stalled filter should then be removed from the unit.

Summary of Contents for 4TEE3C49A1000A

Page 1: ...ts of this product that are capable of conducting electrical current are grounded If grounding wires screws straps clips nuts or washers used to com plete a path to ground are removed for service they must be returned to their original position and prop erly fastened HAZARDOUS VOLTAGE DISCONNECT POWER BEFORE SERVICING WARNING IMPORTANT This document contains a wiring diagram and service informatio...

Page 2: ...389 High 450 CFM 1326 1334 1335 1337 1326 Watts 235 292 347 402 464 Low 290 CFM 1013 1012 1007 993 966 Watts 144 188 232 275 315 Med Lo 350 CFM 1204 1213 1214 1218 1206 3 5 Watts 190 239 292 349 392 tons Med Hi 400 CFM 1375 1381 1382 1386 1373 Watts 257 314 370 430 488 High 450 CFM 1541 1546 1545 1544 1545 Watts 340 405 468 534 595 Low 290 CFM 1211 1220 1227 1225 1212 Watts 195 249 304 357 408 Med...

Page 3: ...C circuit 1 BAYHTR1419 BRKC circuit 2 BAYHTR1415 BRKC with single circuit power source kit BAYSPEK140B circuit 1 BAYHTR1415 BRKC circuit 2 TOTAL HEATER BAYHTR1425BRKC UNIT TEST MODE Unit Test Mode Air Handler The system must be idle or thermostat switched to OFF before the Unit Test will run the air handler The unitwillworkthesamewayineithertheCommunicating Mode or 24 volt AC mode To access the Un...

Page 4: ...4 TEE3C49A SF 1B 2 4TEE3C49A USER INTERFACE MENU ...

Page 5: ...FACE MENU 24V MODE USER INTERFACE ENTER Push left right to scroll through menu options Push up down to scroll through setup menu Push ENTER to make selection Viewing Window User Interface pictured above adjusts variable speed airflow options ...

Page 6: ...rge Air Sensor Open Error 6 Flash N A RAS RNG ERR N A 117 Return Air Temperature Fault Return Air Temperature Range Error RAS SHORT Return Air Sensor Short Error RAS OPEN Return Air Sensor Open Error Y1 ON ERR Y1 Relay Stuck Closed Error Y1 OFF ERR Y1 Relay Stuck Open Error 8 Flash N A TWIN ERROR N A 19 Twinning Fault Air Handler Twinning Error DEMAND ERR Heat Cool Demand Conflict Error HT CFG ERR...

Page 7: ...TEE3C49A SF 1B 7 WIRING DIAGRAM FOR 2 4TEE3C49A ...

Page 8: ...product data improvement it reserves the right to change design and specifications without notice Trane 6200 Troup Highway Tyler TX 75707 For more information contact your local dealer distributor 1 08 OUTLINE DRAWING FOR 2 4TEE3C49A Printed from Dwg D802101 Rev 3 ...

Reviews: