4
18-GE14D1-5
Installer’s Guide
Figure 5. Remove Insulation Strip
Figure 7. Remove Brackets
Figure 6. Remove Screws at Drain Pan
Remove
and
Discard
Replace
with
Narrow
Baffle
For Maximum Efficiency
on Upflow
Figure 4. Baffle Replacement
C. UNIT INSTALLATION
NOTE: Make certain that the unit has been installed in a level
position to ensure proper draining.
UPFLOW
1.
The horizontal drip tray should be removed
for
maximum efficiency
. See Figures 5, 6, and 7.
a.Remove the coil by sliding it out on the coil
channel supports. For the 4TEE3C05, 07, 09, &
10 units, there is a coil support tab at the top of
the coil, connected to the case, that must be re-
moved first.
b.Remove 1" insulation strip covering the lip of
the drip tray. See Figure 5.
c. Detach the tray by removing the two screws at
the drain pan and the two screws holding the
two brackets at the top of the coil. See Figures
6 & 7.
d.Remove drip tray by gently breaking the seal
between the drip tray and drain pan.
2.
Replace the factory installed baffle with supplied
narrow baffle. See Figure 4.
a.Remove the factory installed baffle assembly
from the apex of the coil by using a 5/16"
nutdriver to remove the screws.
b.Replace this baffle with the factory supplied
narrow coil baffle using the screws removed
previously. See Figure 6.
3.
Position unit on Pedestal or other suitable foun-
dation. If Pedestal is not used, a frame strong
enough to support the total weight must be pro-
vided. Provide a minimum height of 14 inches
for proper unrestricted airflow.
When installing the narrow coil baffle, make sure to
align the baffle up with the holes so NOT to puncture
the coil tubing.
▲
▲
CAUTION
!