background image

9

Indoor Blower Performance

Indoor Fan Performance 4DCY4036

Down Airflow

Horizontal Airflow

4DCY4036-HOR

DIPSWITCH SETTINGS

External Static Pressure (in. wg)

AIRFLOW SETTING

1

2

3

4

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

350 CFM/TON

OFF

OFF

OFF

ON

Watts

162

173

197

226

256

285

313

343

360

-

-

CFM

1058

1062

1063

1063

1062

1060

1057

1053

1010

-

-

400 CFM/TON*

OFF

OFF

OFF

OFF

Watts

179

230

265

296

329

366

403

431

436

-

-

CFM

1179

1196

1204

1206

1205

1203

1199

1194

1185

-

-

450 CFM/TON

OFF

OFF

ON

OFF

Watts

318

336

365

399

435

469

502

533

-

-

-

CFM

1390

1376

1370

1366

1361

1354

1349

1351

-

-

-

4DCY4036-DOWN

DIPSWITCH SETTINGS

External Static Pressure (in. wg)

AIRFLOW SETTING

1

2

3

4

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

350 CFM/TON

OFF

OFF OFF

ON

Watts

169

182

210

243

273

301

331

370

433

-

-

CFM

1025

1062

1068

1063

1060

1061

1064

1055

1015

-

-

400 CFM/TON*

OFF

OFF OFF

OFF

Watts

225

253

283

315

348

381

414

449

484

-

-

CFM

1187

1201

1203

1201

1198

1197

1194

1184

1157

-

-

450 CFM/TON

OFF

OFF

ON

OFF

Watts

339

357

390

424

455

483

516

571

-

-

-

CFM

1391

1377

1377

1375

1366

1352

1344

1360

-

-

-

Selection

Low Stage High Stage

7-OFF

8-OFF

A

725

1000

7-ON

8-OFF

B

775

1075

7-OFF

8-ON

C

850

1150

7-ON

8-ON

D

925

1250

4DCY4036

Switch Settings

Nominal Airflow

Auxiliary Heating Airflow, horizontal or downflow from .2 to .6” wg.

4DCY4042A-HOR

DIPSWITCH SETTINGS

External Static Pressure (in. wg)

AIRFLOW SETTING

1

2

3

4

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

350 CFM/TON

OFF

OFF

OFF

ON

Watts

-

160

185

214

245

277

308

339

368

396

423

CFM

-

1206

1211

1213

1215

1215

1214

1212

1208

1201 1190

400 CFM/TON*

OFF

OFF

OFF

OFF

Watts

-

231

261

292

325

359

394

431

467

503

536

CFM

-

1389

1398

1405

1409

1410

1408

1403

1399

1396 1399

450 CFM/TON

OFF

OFF

ON

OFF

Watts

-

326

362

393

421

450

482

517

556

597

-

CFM

-

1582

1592

1593

1587

1577

1566

1557

1553

1556

-

4DCY4042A-DOWN

DIPSWITCH SETTINGS

External Static Pressure (in. wg)

AIRFLOW SETTING

1

2

3

4

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

350 CFM/TON

OFF

OFF

OFF

ON

Watts

-

176

203

232

262

294

325

357

388

417

443

CFM

-

1207

1214

1217

1216

1213

1208

1201

1193

1185 1177

400 CFM/TON*

OFF

OFF

OFF

OFF

Watts

-

253

290

323

355

386

420

455

491

526

558

CFM

-

1405

1411

1413

1412

1407

1399

1389

1377

1366 1357

450 CFM/TON

OFF

OFF

ON

OFF

Watts

-

367

379

409

446

485

522

556

591

633

-

CFM

-

1599

1577

1570

1569

1566

1560

1550

1537

1528

-

Selection

Low Stage High Stage

7-OFF

8-OFF

A

1075

1375

7-ON

8-OFF

B

1100

1450

7-OFF

8-ON

C

1150

1500

7-ON

8-ON

D

1200

1575

Switch Settings

Nominal Airflow

4DCY4042

Indoor Fan Performance 4DCY4042

Down Airflow

Horizontal Airflow

*Factory Default Setting

Summary of Contents for 4DCY4024

Page 1: ... 2014Trane Pub No 22 1799 20 EN Product Data 4DCY4024 through 4DCY4060 Packaged Convertible Dual Fuel 14 SEER 2 5 Ton 60 120 MBTU R 410A 22 1799 20 EN ...

Page 2: ... these products including the compressor have been designed and manufactured for maximum service Every Climatuff compressor is designed and manufac tured to exacting specifications Each design is life tested in extreme envi ronments to ensure reliable and long lasting operation in normal applications Each compressor has internal motor protection for added reliability Single Packaged Convertible Du...

Page 3: ...3 Contents Optional Equipment Listing 4 General Data 5 Indoor Blower Performance 8 TypicalWiring 16 Optional Equipment 14 Dimensional Data 19 Mechanical Specifications 25 ...

Page 4: ...BAYFLTR201B Head Pressure Control Low Ambient Cool 208 240v Kit 5 BAYLOAM105A Quick Start Kit 4DCY4 1 BAYQSKT300A Crankcase Heater Recip 4DCY4024 30 230v 5 BAYCCHT101A Crankcase Heater Scroll 4DCY4042 48 60 230v 5 BAYCCHT102A Crankcase Heater Scroll 4DCY4036 230v 5 BAYCCHT103A Adapter Curb 4DCY4024 36 to BAYCURB030 38 BAYADAP050A Adapter Curb 4DCY4024 36 to BAYCURB033 BAYADAP051A Adapter Curb 4DCY...

Page 5: ...60 1 0 1 7 CENTRIFUGAL 10 X 10 DIRECT VARIABLE SEE FAN PERFORMANCE TABLE 1 2 VARIABLE 208 230 1 60 4 3 4 3 CENTRIFUGAL DIRECT 2 1 20 3350 2600 208 230 1 60 0 34 NO THROWAWAY 4 R410A 6 56 H X W X L 45 86 44 5 52 03 481 385 MODEL RATED Volts PH Hz Performance Cooling BTUH Indoor Airflow CFM Power Input KW EER SEER BTU Watt Hr Sound Power Rating dB A 7 HP Heating Performance High Temp BTUH COP Power ...

Page 6: ...rive No Speeds Motor HP R P M High Low Volts Ph Hz FLA FILTER FURNISHED Type Recommended Recmd Face Area sq ft REFRIGERANT Charge lbs DIMENSIONS Crated in WEIGHT Shipping Net lbs 4DCY4048C1090B 208 230 1 60 47500 1470 3 96 12 0 14 0 73 45000 3 5 3 77 26800 2 3 3 44 8 0 90000 72900 30 60 72000 58320 81 NATURAL LP 1 2 208 230 1 60 33 9 50 50 SCROLL 208 230 1 60 20 5 109 SPINE FIN 2 24 18 01 3 8 EXPA...

Page 7: ...Drive No Speeds Motor HP R P M High Low Volts Ph Hz FLA FILTER FURNISHED Type Recommended Recmd Face Area sq ft REFRIGERANT Charge lbs DIMENSIONS Crated in WEIGHT Shipping Net lbs 4DCY4048A3096C 208 230 3 60 47000 1470 4 03 10 85 14 0 73 42500 3 5 3 56 26800 2 3 3 44 8 0 96000 77500 30 60 72000 62000 80 NATURAL 1 2 208 230 3 60 25 3 35 35 SCROLL 208 230 3 60 13 7 83 1 SPINE FIN 2 24 18 01 3 8 EXPA...

Page 8: ...925 7 ON 8 ON D 700 975 4DCY4024 Switch Settings Nominal Airflow Auxiliary Heating Airflow horizontal or downflow from 2 to 6 wg 4DCY4030 HOR DIPSWITCH SETTINGS External Static Pressure in wg AIRFLOW SETTING 1 2 3 4 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 350 CFM TON OFF OFF OFF ON Watts 112 155 176 199 231 270 299 289 197 CFM 867 905 904 899 904 914 907 840 650 400 CFM TON OFF OFF OFF OFF Wat...

Page 9: ...4DCY4036 Switch Settings Nominal Airflow Auxiliary Heating Airflow horizontal or downflow from 2 to 6 wg 4DCY4042A HOR DIPSWITCH SETTINGS External Static Pressure in wg AIRFLOW SETTING 1 2 3 4 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 350 CFM TON OFF OFF OFF ON Watts 160 185 214 245 277 308 339 368 396 423 CFM 1206 1211 1213 1215 1215 1214 1212 1208 1201 1190 400 CFM TON OFF OFF OFF OFF Watts 23...

Page 10: ...1817 1818 1820 1819 1817 1820 1815 1810 Selection Low Stage High Stage 7 OFF 8 OFF A 1075 1375 7 ON 8 OFF B 1100 1450 7 OFF 8 ON C 1150 1500 7 ON 8 ON D 1200 1575 Switch Settings Nominal Airflow 4DCY4048C 090 can be 1 or 3 Indoor Fan Performance 4DCY4060 Down Airflow Horizontal Airflow Low Stage High Stage 7 OFF 8 OFF A 1375 1800 7 ON 8 OFF B 1450 1900 7 OFF 8 ON C 1525 1975 7 ON 8 ON D 1575 2075 ...

Page 11: ...11 Typical Field Wiring ...

Page 12: ...12 Typical Wiring ...

Page 13: ...13 Typical Wiring ...

Page 14: ...s page are prepared by the manufacturer in order to provide detail regarding job layout only These drawings are not intended to be used as a basis to construct build or modify the items depicted in the drawings The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use ...

Page 15: ...s page are prepared by the manufacturer in order to provide detail regarding job layout only These drawings are not intended to be used as a basis to construct build or modify the items depicted in the drawings The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use ...

Page 16: ...is to construct build or modify the items depicted in the drawings The manufacturer is not respon sible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use BAYFLTR101 201B 1 2 Filter Rack Mounts in Filter Coil Section BAYACCDOR1A BAYACCDOR2A Hinged Filter Access Door Replaces Filter Coil Access Panel Filter ...

Page 17: ...d by the manu facturer in order to provide detail regarding job layout only These drawings are not intended to be used as a basis to construct build or modify the items depicted in the drawings The manu facturer is not responsible for the unauthorized use of these drawings and ex pressly disclaims any liability for damages resulting from such unauthorized use Mixed Air Sensor Economizer Unit Appli...

Page 18: ... not responsible for the unauthorized use of these drawings and expressly disclaims any liability for dam ages resulting from such unauthorized use D C B A E Manual Fresh Air Model Unit Application Models A B C D BAYOSAH001 4YC WC3018 036 4TC 3018 036 4W T Y DCY4024 036 4W Y DCZ6036 22 7 16 20 11 16 12 3 8 9 3 16 BAYOSAH002 4YC WC3042 060 4TC 3042 060 4W T Y DCY4042 060 4W Y DCZ6048 060 25 3 16 20...

Page 19: ...19 Dimensional Data 4DCY4024 through 4DCY4036 1 of 3 ...

Page 20: ...20 Dimensional Data 4DCY4024 through 4DCY4036 2 of 3 ...

Page 21: ...21 Dimensional Data 4DCY4024 through 4DCY4036 3 of 3 ...

Page 22: ...22 4DCY4042 through 4DCY4060 1 of 3 Dimensional Data ...

Page 23: ...23 Dimensional Data 4DCY4042 through 4DCY4060 2 of 3 ...

Page 24: ...24 4DCY4042 through 4DCY4060 3 of 3 Dimensional Data ...

Page 25: ...d on all four sides by louvered panels Indoor Air Fan Direct drive forward curved centrifugal wheel in a Composite Vortica Blower housing Motor shall have thermal overload protection Perma nently lubricated motor bearings Motor blower assembly isolated from unit with rubber mounts Condenser Fan Direct drive draw through propeller type Weather proofed permanent split capacitor fan motor shall have ...