4T-V0-SF-1Q-EN
19
Liquid Line Pressure Transducer
This table shows the corresponding voltage and
pressure readings for the Liquid Line Pressure
Transducer when measured across pins 16 and 17.
35(6685( 36,*
92/76 '&
3,1 72 3,1
Figure 11.
Liquid Pressure Transducer
Pins 16 (White) & 17 (Black)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
A working Liquid Pressure Transducer is required for
the following:
•
Automatic Charging*
•
Diagnostics; Charge Level
The Liquid Pressure Transducer control is measured
across pins 16 and 17 and has an active 0–4.9VDC
transducer input for sensing high liquid pressure.
* Future use
'(6&5,37,21
/2&$7,21
:,5( &2/25
9'& 32:(5
3,1
5('
287387
3,1
:+,7(
&20021
3,1
%/$&.
*5281'
3,1
*5((1
S
SE
EN
NS
SO
OR
RS
S