background image

Tranberg AS | P.O. Box  8033 | N-4068 Stavanger | Norway | Tel.: (47)51 57 89 00 | Fax.: (47)51 57 89 50
E-mail: [email protected] | www.tranberg.com
Tranberg Systems | Hjulmagervej 15C | 7100 Vejle |  Denmark |  Tel.: (45) 75 85 83 80
E-mail: [email protected] |  www.tranbergsystems.com

TEF 2500 400-600 

  

 FLOODLIGHT HPS 400W/600W   USER MANUAL

TECHNICAL DATA

Housing: 

Glass-holding  frame,  latches  and  bracket  made  out  of  stainless  steel,                

Powercoated (RAL 9018) casing. Hard glass pane, resistant against 

temperature changes

Input voltage: 

220 - 240V AC 

Lamp: 

Standard: HPS 400W / 600W

Option:  HPI  400W  (Metal  halide)                                                                                             

Lamp holder: 

E40

Mounting: 

4 mounting holes:

2 x Ø10 dist. 70mm

2 x Ø13 dist. 160mm

IP-rating: 

IP67 ( According to EN60529)

Standard cable entries: 

Brass M24 cable glands

Cable: 

8,9 - 10,4mm

Weight: 

6,6 kg.

DESCRIPTION

Part No.

Floodlight HPS 400W,  220-240V AC Wide Beam

2500 400

Floodlight HPS 400W,  220-240V AC Narrow Beam

2500 401

Floodlight HPS 600W,  220-240V AC Wide Beam

2500 600

Floodlight HPS 600W,  220-240V AC Narrow Beam

2500 601

Summary of Contents for TEF 2500 series

Page 1: ...om www tranberg com Tranberg Systems Hjulmagervej 15C 7100 Vejle Denmark Tel 45 75 85 83 80 E mail mail tranbergsystems com www tranbergsystems com TEF 2500 400 600 FLOODLIGHT HPS 400W 600W USER MANUAL IMPORTANT Read this instruction carefully before installing the product TUM 1016 REV A 10 11 11 25001000_TEGN ...

Page 2: ...always use safety gear suited for the task Be certain to follow codes regulations and or specific procedures that are related to the installation TOOLS REQUIRED Regular tools required for installation Flat small screwdriver PH 1 screwdriver Wrench or similar for fastening the lamp MAINTENANCE INSTRUCTIONS The light should be inspected according to Company routines The manufacturer suggests regular ...

Page 3: ... The installated cable gland is suited for cables with diameters ranging from 8 5 to 13 5mm A replacement kit is supplied and should be used for cable diameters ranging from 13 to 17mm Be sure to install the cable in a way wich prevents water to penetrate into the enclosure through the cable gland CABLE GLANDS 220 240 VAC LAMP BALLAST BOX B Lp N Imax 4 6A Ground L N Lamp Internal connection Extern...

Page 4: ...ess steel Powercoated RAL 9018 casing Hard glass pane resistant against temperature changes Input voltage 220 240V AC Lamp Standard HPS 400W 600W Option HPI 400W Metal halide Lamp holder E40 Mounting 4 mounting holes 2 x Ø10 dist 70mm 2 x Ø13 dist 160mm IP rating IP67 According to EN60529 Standard cable entries Brass M24 cable glands Cable 8 9 10 4mm Weight 6 6 kg DESCRIPTION Part No Floodlight HP...

Reviews: