5. Electrical Installation

•  Before starting the electrical installation make sure the 

power network tension [110V ˜ / 127V ˜ or  

220V ˜ / 230V ˜ ] marked on the device is the same of the 

power network.

•  Make sure that the power line is exclusive and 

connected to the switch board and the wire(s) and the 

circuit breaker(s) are recommended for the device. [look 

on the table of technical specifications].

•  Make sure that the ground wire [green or green/yellow] 

is connected directly to the wire or grounding bus of the 

switch board.

•  If the circut that feeds the device is Phase/Neutral 

[110V ˜ / 127V ˜ or 220V

 ˜

 / 230V ˜ ] use only one circuit 

breaker connected to the phase wire, if the circuit is 

220V ˜ / 230V ˜ Phase/Phase is one bipolar switch.

•  Turn the selector of temperatures for the position “off” 

[pic. 04].

•  For your safety, electrical installation and earthing 

grounding must be executed by qualified persons.

•  The junction box or derivation must be located 15 cm 

above the wall-mounted water outlet connection outlet.

•  The earthing grounding system ensures your safety when 

using domestic appliances.

Extension

Pressure

Reducer

Senseday

Shower

Extension

Pressure

Reducer

Senseday

Shower

03

02

01

Extension

Pressure

Reducer

Senseday

Shower

Extension

Pressure

Reducer

Senseday

Shower

IMPORTANT FOR YOUR SAFETY

 

To reduce risk of electric shocks, this ground 

wire [green wire] in this appliance must be 

connected to a groundingn earthing system, 

in accordance with the instalattion norm.

WARNING

Before starting electrical installation, 

turn off the mains switch or circuit 
breaker where the 

Senseday Shower 

is installed. 

WARNING

05

04

Encaixar a capa

do Prolongador

no Alojamen

to

do Cor

po da Ducha

Attach the Extension 

cover to the Housing in 

the Shower Body

6. Replacing the Electrical Coil

•  Turn off the mains switch or circuit breaker and cut the 

water supply.

•  Loosen the top nut rotating it counterclockwise 

[pic.08].

•  Hold the electric coil box assemble tight with one hand 

and support rubber diaphragm with fingers [pic.09].

•  Pull up the entire electrical box assembly. Pull the 

resistance assembly until you undock it [pic.10].

Before replacing the electrical coil, 

always cut water supply and turn off  

the mains switch or circuit breaker  

where the appliance is installed to 

reduce the risk of electric shock.

WARNING

10

Prolongador

Capa do

Prolongador

Redutor

de Pressão

Ducha 

Sense Day

Prolongador

Capa do

Prolongador

Redutor

de Pressão

Ducha 

Sense Day

Prolongador

Capa do

Prolongador

Redutor

de Pressão

Ducha 

Sense Day

08

09

English

Prolongador

Capa do

Prolongador

Redutor

de Pressão

Ducha 

Sense Day

•  Use appropriate conector [in porcelain] to connect the 

connecting cables of the 

Senseday Shower 

to the 

feed wires of the power network. This conector is not 

supplied with the device. [pic. 07].

•  The junction box should be at a height of 2,25m from 

the floor.

06

07

Prolongador

Capa do

Prolongador

Redutor

de Pressão

Ducha 

Sense Day

Prolongador

Capa do

Prolongador

Redutor

de Pressão

Ducha 

Sense Day

Never use plug and socket 

in the installation [pic 06]

FOR YOUR SAFETY

WARNING

Summary of Contents for senseday

Page 1: ...with the product to the wall mounted connection Attach the Senseday Shower to the end of the extension Apply thread seal tape to the Senseday Shower thread wrapping around the thread 3 to 4 times pic 03 The connection thread embedded in the wall should be diameter of If you have not use a reduction bush by also applying the tape to seal the thread Attach the appliance manually Do not use tools in ...

Page 2: ...re starting electrical installation turn off the mains switch or circuit breaker where the Senseday Shower is installed WARNING 05 04 E n c a i x a r a c a p a d o P r o l o n g a d o r n o A l o j a m e n t o d o C o r p o d a D u c h a Attach the Extension cover to the Housing in the Shower Body 6 Replacing the Electrical Coil Turn off the mains switch or circuit breaker and cut the water supply...

Page 3: ...e off position The Shower does not heat up Inadequate wiring Please contact a qualified Professional to verify whether the conductors are in compliance with the ones specified in this manual Low electrical tension Please contact a qualified Professional to verify whether the electrical tension is in accordance with nominal values 110V 127V or 220V 230V If it is please contact your local sales repr...

Page 4: ...ay Tramontina se desarrolló de acuerdo a rigurosos estándares técnicos para mayor seguridad comodidad y facilidad de utilización Lea atentamente todas las instrucciones de instalación y garantía antes de instalar el producto Guarde este manual para futuras referencias En caso de dudas entre en contacto con sac tramontina net 2 Características Técnicas MODELO 3 TEMPERATURAS 4 400 W Tensión Nominal ...

Page 5: ...za la seguridad durante la utilización de aparatos electrodomésticos Antes de iniciar la instalación eléctrica apagar la llave general o disyuntor del circuito eléctrico donde esté instalada la Ducha Senseday ATENCIÓN Español Extensión Reductor de Presión Ducha Senseday 02 01 E n c a i x a r a c a p a d o P r o l o n g a d o r n o A l o j a m e n t o d o C o r p o d a D u c h a Prolongador Capa do...

Page 6: ...ucha Sense Day Prolongador Capa do Prolongador Redutor de Pressão Ducha Sense Day 08 09 Pujar para arriba todo el conjunto de la caja eléctrica Con la otra mano pujar el conjunto resistencia hasta desacoplarlo Asegurese de que la nueva resistencia es de la misma potencia y voltaje de la instalación eléctrica Ubicar la nueva resistencia Tramontina sobre los apoyos Verificar que solamente se encajan...

Page 7: ...selector de manera que quede en una temperatura agradable 9 Certificado de Garantía Presentar la Boleta de Compra del producto es fundamental para tener derecho a la garantía Asistencia Técnica Autorizada Tramontina consulte el sitio www tramontina com Tramontina garantiza este producto contra eventuales defectos de fábrica por un plazo de 12 meses incluyendo la garantía legal a partir de la fecha...

Page 8: ...senseday ...

Reviews: