![Tramontina senseday Instruction Manual Download Page 1](http://html1.mh-extra.com/html/tramontina/senseday/senseday_instruction-manual_1148756001.webp)
1. Presentation
3. Important for your safety
Read before Installing
4. Hydraulic Installation
• This appliance must be installed by qualified persons.
• It is compulsory to turn off the circuit breaker
whenever this appliance is installed, serviced, or
cleaned.
• Never connect accessories or devices to this
appliance that are not recommended by this manual
or by the manufacturer.
• To avoid hazards, the supply cord of the appliance
and other electrical components should only be
replaced by the manufacturer or its
Authorized
Technical Support
. The user is only allowed to
replace the electric coil.
• This appliance can heat up water to a temperature
higher than that is adequate safe for use, which can
cause burns. Children, elderly people, sick people,
or people with a physical/mental disability must be
supervised when using the appliance. To do that,
special precautions should be taken to appropriately
regulate water temperature before and during use.
PREPARING
• For correct operation of the
Senseday Shower
, it is
recommended that the installation point be at least 1m
below the water tank and 2.1 meters above the floor
[pic.01].
• When the gap between the installed water tank and
the
Senseday Shower
is too large [in tower blocks, for
example], or when the supply comes directly from the
a public drinking water supply, please use the pressure
reducer included with the appliance [pic.02]. For pressure
above 80 kPa [8 m.c.a], please use reducer included with
appliance.
• Before attaching the
Senseday Shower
, let water run
through pipes for a few seconds to remove dirt or any
other residue.
• Attach the extension included with the product to the
wall-mounted connection. Attach the
Senseday Shower
to the end of the extension.
• Apply thread seal tape to the
Senseday Shower
thread,
wrapping around the thread 3 to 4 times [pic.03].
• The connection thread embedded in the wall, should be
diameter of ½”. If you have not, use a reduction bush,
by also applying the tape to seal the thread.
• Attach the appliance manually. Do not use tools in order
to avoid damaging the item.
• Engage the extension cover in the shower body housing.
[pic. 02].
Tramontina’s Senseday Electric Shower
was developed under strict technical regulations for
increased safety, comfort, and ease of use.
Please read all assembly instructions and the
warranty before installing the product.
Keep this manual safe for future reference.
If you have any questions, please contact
2. Technical Specifications
MODEL
3 TEMPERATURES
4 400 W
Voltage Rating
110V ˜
127V ˜
220V ˜
230V ˜
Nominal
Wattage [W]
0 Off
0
0
1 Warm
2 850
2 850
2 Hot
4 400
4 400
Circuit Breaker or Fuse [A]
40
25
Minimum Wiring [mm²]
10
4
Maximum Distance [m]*
20
40
MODEL
3 TEMPERATURES
5 500 W
Voltage Rating
110V ˜
127V ˜
220V ˜
230V ˜
Nominal
Wattage [W]
0 Off
0
0
1 Warm
3 200
3 200
2 Hot
5 500
5 500
Circuit Breaker or Fuse [A]
50
32
Minimum Wiring [mm²]
10
4
Maximum Distance [m]*
27
32
Degree of Protection
IP24
Operational
Pressure
Minimum
10 kPa [1 m.c.a.]
Maximum
400 kPa [40 m.c.a.]
Hydraulic Connection [Input]
Thread - ½ BSP
THE RESISTIVITY OF WATER SUPPLIED TO THIS PRODUCT MUST NOT BE
LOWER THAN 1,300 OHMS . CM AT 22°C.
* FOR DISTANCES ABOVE THOSE INDICATED IN THIS TABLE USE LARGER
SECTION CONDUCTORS.
THIS PRODUCT IS COMPLIANT WITH THE