TrakPower TKPC0212 Instructions Download Page 3

3

into one 7.4V pack. Once wired in series, connect the battery’s 
open 4mm positive (+) terminal to the LiPo balancer’s red (+) 
lead, and the battery’s open 4mm negative (-) terminal to the 
balancer’s black (-) lead. Connect the adapter’s smaller (2mm) 
male terminal to the small jack that is attached to the jumper 
lead as shown. 

IMPORTANT:

 You 

MUST

 charge saddle packs as 

one 7.4V pack. 

Do NOT

 charge the 3.7V modules separately.

                            2S−4S Hardwired LiPo Packs

Power wires

Balance Lead

 2S-4S Hardwired LiPo Packs:

 For charging 2S-4S hardwired 

LiPo batteries, the balance lead will need to be connected to 
the proper balance adapter and the power wires will need to 
be connected to the charger. It is imperative that the proper 
balance adapter is chosen for charging.

                             2S LiPo Receiver Packs

Power wires

Balance Lead

2S LiPo Receiver Packs:

 For charging 2S LiPo receiver 

packs, the balance lead will need to be connected to the 
proper balance adapter and the power wires will need to be 
connected to the charger via radio jack or universal charge 
lead adapter. It is imperative that the proper balance adapter 
is chosen for charging. 

 8.   

NEVER

 leave the room where the battery is until charge has 

fi nished.

IMPORTANT: 

NEVER allow a battery’s positive and 

negative leads to accidentally touch each other, as 
a short-circuit condition will result and permanently 

damage the battery and/or charger. Disconnect the battery and 
remove input power from the charger immediately if the battery 
begins to swell or becomes hot!! Be sure to wear protective gloves 
when moving the battery in case it has become hot.

IMPORTANT WARNINGS FOR CHARGING LIPO BATTERIES:

   NEVER allow a LiPo cell to exceed 4.20V maximum at 

any time.

   NEVER allow LiPo cells to exceed 140°F (60°C) during 

charge, as they can and USUALLY WILL become 
damaged and possibly catch FIRE!!

   NEVER allow a LiPo to continue charging if the battery 

begins to swell or smoke begins to emit from the pack, 
as this is an indication the pack is damaged and a 
catastrophic failure could occur soon. Disconnect the 

battery and leave it in a safe, fi reproof location for 
approximately 1 hour.

   NEVER allow a LiPo to continue with the charge process 

if the charger fails to recognize full charge. Disconnect 
the battery immediately, as pack failure could result.

   NEVER attempt to charge a battery that has previously 

overheated, discharged below 2.50V, or which has been 
damaged in any other way. Dispose of the battery.

   LiPo cells should be charged about once per year at a 

minimum to prevent over-discharge.

   LiPo batteries should be stored with about 30%-50% 

of capacity.

   ALWAYS keep out of reach of children.

Discharging LiPo Batteries

WARNING!! 

NEVER allow TrakPower LiPo cells to 

discharge below 2.5V per cell as permanent cell damage 
could result. This can also result in some chargers not 

recognizing the battery upon recharge, preventing the battery 
from being charged again. ALWAYS make sure batteries are 
physically and electrically undamaged before charge or discharge.

1. When powering an ESC:

 

a.   Do NOT use an ESC unless it’s LiPo compatible.

 

b.   Follow the ESC’s instructions carefully to set the proper low 

voltage cutoff  point for the battery. As an extra measure of 
safety and to maximize the lifespan of the TrakPower battery, 
it’s recommended to not allow the battery to discharge 
below 3.20V per cell.

  c.  ALWAYS disconnect LiPo batteries completely from 

electronic speed controls when not in use to prevent 
accidental over-discharge.

2. When using a battery discharger:

  a.  Choose an isolated, fi re-

proof area to discharge 
the battery as explained 
on page 2.

  b.  Choose a LiPo compat-

ible discharger which 
has balancing capabili-
ties. Or, use a LiPo com-
patible discharger in 
conjunction with a separate LiPo balancer.

  c.  Set the discharge cutoff  voltage to 3.20V to 3.40V per cell for 

TrakPower LiPo batteries. NEVER discharge a LiPo to 2.5V or 
below at any time as permanent failure will result.

  d.  Set the discharger’s output current to an appropriate value 

for the battery.

  e.  Connect the battery’s main lead and balancing lead to the 

discharger as described in the discharger’s instructions. 
ALWAYS connect a charge adapter lead to the charger BEFORE 
connecting the battery to the charger.

 

f.  If possible, as another extra safety measure, use a discharger 

that also includes a temperature monitoring function that can 
stop charge if the battery exceeds a specifi ed temperature. 
Set the discharger’s maximum temperature to 115°F (46°C).

  g.  NEVER leave the room where the battery is being discharged.

Battery

Nominal 

Voltage

*Minimum

Discharge

Voltage

2S
3S
4S
5S
6S

7.4 V

11.1 V

14.8 V
18.5 V

22.2 V

6.4 V
9.6 V

12.8 V
16.0 V
19.2 V

* Recommended, based on 3.2 V per cell