Trainer NF1200-T Operator'S Manual Download Page 6

Handle

An  easy-grip  carrying  handle  for  increased  portability  of  the  i-PAD 
NF1200-T.

Cover

Covers  the  front  panel  of  the  i-PAD  NF1200-T  and  retains  the 
defibrillator electrode pads package.

SHOCK button

Press  this  button  when  the  i-PAD  NF1200-T  prompts  you  to  “Press 
the flashing orange button now”.
Pressing  this  button  delivers  a  simulated  defibrillation  shock  to  the 
manikin.

AED electrode pads 
connector port

Plug the connector of the AED electrode pads into this port

Graphical Rescue 
Guide

Guides  you  by  indicating  the  current  step  in  the  simulated  rescue 
process.

Quick Reference 
Guide

A  printed  card  that  summarizes  the  steps  of  a  simulated  rescue 
process using the i-PAD NF1200-T.

Battery Pack

Provides power to the i-PAD NF1200-T.

IrDA
Communication 
Port

This port is disabled in this version of the i-PAD NF1200-T.

Remote Control 
Sensor

Senses the infrared control signal from the remote controller. Point 
the  remote  controller  at  this  sensor  when  you  want  to  control  the 
i-PAD NF1200-T.

NF1200-T

6

CU Medical Systems, Inc.

Summary of Contents for NF1200-T

Page 1: ...i PAD NF1200 T Operator s Manual AED Trainer...

Page 2: ...up the i PAD 8 Package Contents 8 Infrared Remote Controller Remocon 9 Rescue Scenarios 11 Setting up the i PAD NF1200 T 14 4 Using the i PAD NF1200 T 15 Simulated Rescue Preparation 15 Simulated Mai...

Page 3: ...ended rescue protocol of international rescue policy making bodies such as the American Heart Association the European Resuscitation Council and the American Red Cross It is to be used in conjunction...

Page 4: ...ntation NF1200 T 4 CU Medical Systems Inc State LED Power ON OFF button Remote control sensor i Button Handle Cover Turn ON First 1 ON OFF Then Open 1 Turn ON 2 Top View of the i PAD NF1200 T with its...

Page 5: ...AD NF1200 T blinking green the i PAD NF1200 T is in standby mode and ready for a rescue operation solid green the i PAD NF1200 T is in rescue mode blinking red the i PAD NF1200 T detected a system err...

Page 6: ...g the connector of the AED electrode pads into this port Graphical Rescue Guide Guides you by indicating the current step in the simulated rescue process Quick Reference Guide A printed card that summ...

Page 7: ...5 non condensing Do not store the device near heating equipment Do not install or store in environments where humidity tends to rapidly increase or there is a ventilation problem Do not store the devi...

Page 8: ...ntains the following items NF1200 T 8 CU Medical Systems Inc Turn ON First 1 ON OFF Then Open 1 Turn ON 2 i PAD NF1200 T Disposable non rechargeable battery pack Rechargeable battery pack option Batte...

Page 9: ...roller should be pointed at the remote controller sensor of the i PAD NF1200 T when controlling its operation The instructor should control the i PAD NF1200 T using this Remote Controller only Any cha...

Page 10: ...trainee attaches the pads to the manikin pressing this button simulates the attachment of the pads and starts rescue scenario 1 LOW BAT Simulates a low battery condition when pressed UP Increases the...

Page 11: ...Shock delivery c CPR administration 30 chest compressions 2 artificial breaths d Shockable rhythm e Second Shock delivery f Normal Sinus Rhythm g CPR administration 30 chest compressions 2 artificial...

Page 12: ...y c CPR administration 30 chest compressions 2 artificial breaths d Shockable rhythm e Second shock delivery f CPR administration 30 chest compressions 2 artificial breaths g Normal Sinus Rhythm h CPR...

Page 13: ...ificial breaths g Shockable rhythm h Third shock delivery i CPR administration 30 chest compressions 2 artificial breaths j Normal Sinus Rhythm k CPR administration 30 chest compressions 2 artificial...

Page 14: ...NF1200 T Study the functions of the buttons switches indicators and connection ports Place the trainer defibrillator pads package as shown in the following figures Install the battery pack Place the...

Page 15: ...State LED turns solid blue Beeper emits a short continuous beep State LED turns solid green Voice prompt Attach pads The voice prompt is played until the training instructor presses the PAD ON OFF or...

Page 16: ...pads 5 Take the pads out of its packaging NF1200 T 16 CU Medical Systems Inc CAUTION To the training instructor Emphasize the following caution to the trainee Do not waste time in removing the patien...

Page 17: ...the AED electrode pads connector port of the i PAD NF1200 T 7 Look at the graphics on the back of the pads The graphics indicate the positions of the pads on the patient s body 8 Peel off the protect...

Page 18: ...ted The i PAD NF1200 T begins rhythm analysis simulation as soon as the training instructor presses the PAD ON OFF button or any scenario button from S1 to S8 The i PAD NF1200 T activates the followin...

Page 19: ...until the i PAD NF1200 T disarms itself if the SHOCK button is not pressed within 15 seconds Voice prompt Press the flashing orange button now Deliver shock now SHOCK button backlight flashing orange...

Page 20: ...In the real i PAD NF1200 device the CPR protocol depends on the following settings 1 Rescue Provider Lay Rescuer Healthcare Provider 2 Compression Ventilation Ratio 30 2 30 compressions 2 breaths 15 2...

Page 21: ...has been delivered Voice Prompt Check pulse Beeper 1 second continuous beep i PAD NF1200 T pauses for 10 seconds to allow the trainee to check the pulse of the simulated patient Voice Prompt Begin CP...

Page 22: ...nute The number of beats depends on the Compression Ventilation ratio setting 30 2 setting 30 beats 15 2 setting 15 beats Push the chest of the patient hard and fast in time with the beat provided by...

Page 23: ...the result of service or modification by an entity other than CU Medical Systems Inc or its authorized representatives IN NO EVENT SHALL CU MEDICAL SYSTEMS BE LIABLE FOR CONSEQUENTIAL DAMAGES Only pr...

Page 24: ...d by the user When the i PAD NF1200 T is not operating properly immediately bring it for servicing to an authorized service center Please fill up the following table with the necessary information whe...

Page 25: ...wha Medical Instrument Complex 1647 1 Dongwha Munmak Wonju Gangwon Republic of Korea Tel 82 33 747 7657 Fax 82 33 747 7659 EU Authorized Respresentative of CU Medical Systems Inc Medical Device Safety...

Page 26: ...Dongwha Medical Instrument Complex 1647 1 Dongwha Munmak Wonju Gangwon Republic of Korea Tel 82 33 747 7657 Fax 82 33 747 7659 Homepage www cu911 com i PAD NF1200 T AED Trainer...

Reviews: