Trafomatic Audio TARA 30A User Manual Download Page 5

ENVIRONMENT

1) 

Water and Moisture.

 Do not use this product near water - i.e. near a bathtub, ash bowl, 

    kitchen sink or laundry tub; in a wet basement; or near a swimming pool or the like. Damp      

    basements should be avoided.

2) 

Heat.

 The product should be situated away from heat sources such as radiators, heat registers, 

    stoves or other appliances that produce heat. Also avoid putting the unit in the direct rays of the sun. 

3) 

For indoor use only.

 

PLACEMENT

1) 

Accessibility.

 It is normal for an audio device to run warm if used for prolonged periods.

    Always place your device away from children and pets to prevent burns.

2) 

Ventilation.

 Proper ventilation is critical for safe and reliable operation of all vacuum tube 

    based equipment. This product should not be placed in a built-in installation or rack unless proper

   ventilation is provided or the manufacturer’s instructions have been followed. Never place any thing on 

   top of your preamplifier that could obstruct airflow and cause vacuum tubes to over heat and damage  

   the unit. Do not place your preamplifier in a closed bookcase; overheating could occur. 

   Ensure that there is at least 6” (150 mm) of open space above the preamplifier.

3) 

Surface.

 Place the unit on a flat level surface. Care should be taken to prevent objects from 

     falling and liquids from spilling into the unit. Do not subject the unit to excessive smoke, dust, 

     vibration or shock. 

MAINTENANCE

1) 

Cleaning.

 Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners 

     or aerosol cleaners. Use a dry cloth for cleaning. Do not use any type of abrasive pad, scouring 

     powder or solvent such as alcohol or benzene.

2)  

Tube replacement.

 Vacuum tubes have life in the 10.000 hours range. We recommend replacing the   

      tubes after 36 months, depending on your listening habits. That will ensure that the preamplifier always 

     performs at its best and tube failure will not overstress other parts of the unit.

3) 

Biasing the amplifier.

 Biasing of the 

TARA 30A preamplifier

 is not required. However, for best 

     performance it is recommended to adjust dynamic balance, as described in the Controls section 

     further below.

SERVICE

1) 

Replacement Parts.

 When replacement parts are required, be sure that the service technician

    uses replacement parts specified by the manufacturer or parts with the same characteristics 

    as the original part. Unauthorized substitutions may result in fire, electric shock or other 

    hazards.

2) 

Tube replacement.

 Should it become necessary to replace the vacuum tubes, remove the 

    AC power plug from the wall and allow thirty minutes (30 min) for the high voltage capacitors 

    to discharge. Follow instructions outlined below in the section “Handling vacuum tubes”.

3) 

Modifications.

 Modifications to the amplifier are strongly discouraged. The unit was designed

    by experienced engineers and tested for safe and reliable operation. Any modification may 

    poses safety risk and result in reduced lifetime of the product. Any removal of the cover will 

    void warranty.

04

TARA 3

0A - Line Level Preamplifier - 

User Manual

Summary of Contents for TARA 30A

Page 1: ...www trafomaticaudio com Rev 1 www trafomaticaudio com Rev 1 TARA 30A Line Level Preamplifier ...

Page 2: ...ontrols and Their Functions 08 Front Panel 08 Rear Panel 10 Servicing 11 Technical Specifications 12 Table of Contents Section Page No Safety Precautions 02 Getting Started 05 About Your Line Preamplifier 05 Packaging Preparation for use 06 Controls and Their Functions 08 Front Panel 08 Rear Panel 10 Servicing 11 Technical Specifications 12 ...

Page 3: ...quate wire cross section and an electrical outlet that is grounded If you do not know whether the outlet is grounded consult your electrician or local power company 6 Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on or pinched Pay particular attention to cords at plugs convenience recep tacles and where they exit from the product Always use powe...

Page 4: ......

Page 5: ...nplug this product from the wall outlet before cleaning Do not use liquid cleaners or aerosol cleaners Use a dry cloth for cleaning Do not use any type of abrasive pad scouring powder or solvent such as alcohol or benzene 2 Tube replacement Vacuum tubes have life in the 10 000 hours range We recommend replacing the tubes after 36 months depending on your listening habits That will ensure that the ...

Page 6: ...tility HANDLING AND REPLACING VACUUM TUBES Many people have never had experience handling vacuum tubes Process is very similar to handling incandescent light bulbs As with the light bulbs you should not touch a vacuum tube when it is operating since you can burn yourself Similarly if a tube is dropped on a hard surface it may break or change critical operating parameters When replacing the tubes a...

Page 7: ...0A has dual power supply and both cables must be connected Plug in the power cord Connect LINE OUTPUTS of the TARA 30A to line inputs of your amplifier Connect your audio source s to the preamplifier s input s rca1 and xlr1 through xlr3 If some of your sources require signal grounding turntable tonearm for example connect the wire to the grounding lug GND on the rear panel of the power supply unit...

Page 8: ......

Page 9: ...cs or during integration with subwoofers The front panel also has the power on light and window for the remote control receiver LEFT SIDE OF THE UNIT Power ON OFF switch The switch turns the preamplifier ON and OFF When turning on the preamplifier make sure that the volume control is at its minimum The preamplifier will be fully functional after only 30 seconds However as it warms up over the firs...

Page 10: ... be used with the 230V line Fuses are glass cartridge 5x20mm AC input connector AC line voltage selector switch This switch needs to be set so that the number displayed 115 or 230 corresponds with the line voltage in your country CONTROLS AND THEIR FUNCTIONS Line outputs connectors Power connector 1 Power connector 2 Power connector 2 Power connector 1 Line outputs connectors Fuse R L 09 TARA 30A ...

Page 11: ...me pro vides unmatched flexibility when it comes to optimizing performance in complex systems with multiple inputs and outputs Instead of providing a single point of the ground loop break the TARA 30A employs multiple ground lift switches which can break ground loop s in a way that is the most beneficial for your specific system configuration CENTRAL GND LIFT removes ground from all inputs and out...

Page 12: ......

Page 13: ...nob is rotated until the instrument is in the central position reading 0 mV It is recommended that the balancing is done a two minutes after powering the preamplifier on when the tubes stabilized their operating conditions NOTE while the Dynamic Balancing is beneficial to the performance of the unit there is no need to continuously readjust the setting during the listening A slight drift of a few ...

Page 14: ...NTENANCE section In an unlikely case that the unit does not operate as intended please contact factory or your local distributor for assistance CAUTION Lethal voltages are present inside the amplifier Do not remove the preamplifier s covers Servicing of the unit should be performed only by authorized service personnel 13 TARA 30A Line Level Preamplifier User Manual ...

Page 15: ...mers S N 98dB Inputs 3x XLR 1x RCA Outputs 2xRCA 2xXLR by channel Output Impedance 25 Ohms XLR and RCA Frequency Response 5Hz 200KHz 1dB Vacuum Tube Complement 2x 6N30P 6N6P 4x EML 30A Power supply Low Induction toroid transformer by Trafomatic Audio High Inductivity custom made chokes Mundorf MLytic HV type Requirements 230V 50Hz 115V 60Hz switchable Power consumption 200VA Weight 22 kg with powe...

Page 16: ...www trafomaticaudio com TARA 30A Line Level Preamplifier ...

Reviews: