Installing Lead Acid Batteries in SafePace Evolution Signs
potential hazard. The Lithium batteries supplied with the SafePace EV12FM sign are
stable and safe when handled and used properly. Do not bend the batteries or
attempt to puncture them with sharp objects as this could cause a fire and/or
explosion.
To install the battery in the battery bracket:
1.
Make sure that the battery has been removed from its packaging, then open the sign enclosure.
2.
Make sure the velcro straps on the battery enclosure are separated.
3.
Place the battery into the lower bracket then push the battery flat against the enclosure. You should
hear it snap into place.
4.
Use the velcro straps to secure the battery in place in the enclosure.
5.
When the battery is secured in place, connect the battery and sign power connectors to power on the
sign.
Installing Lead Acid Batteries in SafePace Evolution Signs
The battery should be placed with care into the battery bracket inside the sign. There are two parts to the
battery bracket: the upper bracket and the lower bracket. You need to remove the upper bracket, install the
battery, then replace the upper bracket to keep the battery in place.
Figure 21: Lead acid battery inserted and connected
N
OTE
:
This image is for illustrative purposes only and the number of batteries in your sign may be
different from that shown.
W
ARNING
:
Proper battery care and maintenance is required. Improper care and maintenance of
batteries may void the product warranty. We strongly recommend that you do the following:
• Replace the batteries every TWO years, in order to prevent damage to the sign.
SafePace® Evolution 12FM Installation Manual