www.trafag.com

    

M12x1

   

   

93

Ø 32

48

45.5

Ø 37

SW27 / Ø 29.5

335° max. 2.5 Nm

343° max. 5 Nm

838X

.XX.XXXX.

35/32

.XX.XX

G1

/4

M5x7

12

2

Seal

DIN3869

838X

.XX.XX

17

.XX.XX.XX

54 ... 60

~Ø20

838X

.XX.XXXX.XX.XX.

33

   10      14.5   

Ø29.5

R1/4"

Ø5.05x3U

M5x7

SW27

DIN3858

838X

.XX.XX

19

.XX.XX.XX

   

   3   

   20       14.5   

Ø 6

G1/2" 

SW27

Ø 29.5

838X

.XX.XX

11

.XX.XX.XX

   15.1      2   

   14.5   

SW27

Ø 29.5

Ø 

5.05x3U

1/4" NPT

M5x7              

838X

.XX.XX

30

.XX.XX.XX

   13.5      6.5      14.5   

1/2" NPT

Ø 

5.05x3U

SW27

M5x7              

Ø 29.5

838X

.XX.XX

51

.XX.XX.XX

11

14.5

13.5

Ø5.05x3U

M5x7

Ø29.5

M14x1.5 DIN6149-2

SW27

838X

.XX.XX

31

.XX.XX.XX

   12.5   

   14   

   20   

   14.5   

Ø

21

M5

G1/4"

838X

.XX.XX

10

.XX.XX.XX

7/16“-20UNF DIN3866

13.5

838X

.XX.XX

18

.XX.XX.XX

   9       2.3   

 Ø 29.5

 M5x7

 7/16"-20UNF SAE4 (J1926)

SW27

838X

.XX.XX

42

.XX.XX.XX

7/16"-20UNF SAE J512

Ø20

8.6

1.5

838X

.XX.XX

24

.XX.XX.XX

(28.5)

14 3 11.5

G1/2"

Seal
DIN3869

DIN3852-E

M 5x7

 Ø 29.5

SW27

838X.

XX.XX

41

.XX.XX.XX

Dimensions

30°

R1

G3/4"

Bore  

M 2:1

G3/4"

2.7

16

O-Ring

Ø20x1.5

Sealing DIN/ISO 3869
23.9x29.2x1.5

SW36

11.5

Ø 23 H8

Ø 10

Ø 39

16

Ra1.6

8380

.XX.XX

52

.XX.XX.XX

G3/4"

Ø 23

Ø 50

16

Welding flange for  
G3/4” frontal membrane (1.4301) 
Ordering No. C27805

Summary of Contents for 8380 DPC

Page 1: ...g to instructions Electrical connection Type 838X XX XXXX S N YYYYYY ZZZ 16 16 Range 1 9 bar G max 20 bar Us 1 15 30V DC Us 3 Out 2 SP1 4 SP2 5 Measuring range Type code Serial number Max overpressure Supply positive Supply voltage Switching output Manufacturing date W Y Type label description Pin assignment Output signal supply voltage Output ISUPPLY USUPPLY 4 20 mA 30 mA 15 30 VDC 0 10 VDC 30 mA...

Page 2: ...of the measuring equipment P U I Us Shield Out Out analogue SP1 SP2 Us The use of a shielded cable is recommended ü t P ON OFF ON OFF Fno Fnc FL FH t P ON Hno OFF ON Hnc OFF dS dr rP SP t P ON Hno OFF rP SP ON Hnc OFF Hysteresis Window Delay P US US I SP1 SP2 RL US earth Connection of loads to switching output ...

Page 3: ...X XX51 XX XX XX 11 14 5 13 5 Ø 5 05x3U M5x7 Ø 29 5 M14x1 5 DIN6149 2 SW27 838X XX XX31 XX XX XX 12 5 14 20 14 5 Ø 21 M5 G1 4 838X XX XX10 XX XX XX 7 16 20UNF DIN3866 13 5 838X XX XX18 XX XX XX 9 2 3 Ø 29 5 M5x7 7 16 20UNF SAE4 J1926 SW27 838X XX XX42 XX XX XX 7 16 20UNF SAE J512 Ø20 8 6 1 5 838X XX XX24 XX XX XX 28 5 14 3 11 5 G1 2 Seal DIN3869 DIN3852 E M 5x7 Ø 29 5 SW27 838X XX XX41 XX XX XX Dim...

Page 4: ...ut end point Damping analogue output rise time 10 90 nominal pressure 0 01 3 00 s Display rotate no yes 180 Display mode actual highest lowest off act 1 decimal act 2 dec act 3 dec Display update rate 1 2 5 20 Hz Diagnostic mode Sampling time for logger 0 1 999 9 s off 0 Access code 4 digit code Factory use By pressing simultaneously the menu will return to the base dis play or automatically after...

Reviews: