background image

 

 

 

 

 

 

 

 

 

 

Directory

.

 

Important safety instructions

.

 

Precautions for user

.

 

Fault

 

Code Indication

.

 

Panel control

 

.

 

Protection function

.

 

Caution in use

.

 

Common Faults Removing

 

.

 

Maintenance of Machine

 

.

 

Technical parameters

.

 

What in the box

Summary of Contents for TDJ2481E

Page 1: ...Dehumidifier TDJ2481E Instruction For User ...

Page 2: ...Thank you for buying Dehumidifier Please read the instruction carefully in order to use the machine safety and properly And please keep this instruction safety for the time you need it ...

Page 3: ...rtant safety instructions Ⅱ Precautions for user Ⅲ Fault Code Indication Ⅳ Panel control Ⅴ Protection function Ⅵ Caution in use Ⅶ Common Faults Removing Ⅷ Maintenance of Machine Ⅸ Technical parameters Ⅹ What in the box ...

Page 4: ...before cleaning or maintain the machine Don t use in arrow and sealed space make sure to connect the ground lead Don t do any change of machine unless guiding by our technicians Attention The machine hasloss and dislocation phase protector when the connected three phases outer power supply is not correct as the machine setting the protector will be disconnected all the indicator on control panel w...

Page 5: ...protection of compressor will be acted if use it in the environment temperature higher than 38 and stop running automatically it will reduce the working life of the machine Below 5 absolute humidity of the environment is quite low do not use the machine if not necessary Do make sure to leave at least 50 cm from wall to air inlet and at least 50 cm from wall to air outlet when the machine used agai...

Page 6: ...dusty environment to avoid malfunction and raise the working life Don t cut off the power or pull out plug when machine running Don t damage the power line or make any change Don t put fingers or sticks into the air outlet Don t do any change of machine unless guiding by our technicians Ⅲ Fault code indication E1 Coil temp sensor fault PP Freon leakage cooper tube block E2 E5 Temp humidity senor f...

Page 7: ...ting mode 3 Press the key to set the humidity value up with 1 RH scale in running mode Press the key to set the hours up with 1 hour scale in timed on off setting mode 4 Press the key to set the humidity value down with 1 RH scale in running mode Press the key to set the hours down with 1 hour scale in timed on off setting mode ...

Page 8: ... Blinking when in timed on off setting mode 9 Ambient temperature display 10 Dehumidifying Light on when in standby mode and running mode Blinking when in the 3 minutes delay protection mode Ⅴ Protection function 1 Automatic defrost protection function The dehumidifier will defrost automatically when it frost on a certain level on the evaporator compressor shutdown The dehumidifier will start auto...

Page 9: ... scope of the machine is 5 38 3 The room temperature will go up 3 from compressor heat dissipation when dehumidifier running it s normal phenomenon please feel free to use 4 It s not necessary to use dehumidifier when the room temperature is below 10 the absolute humidity is quite low at this condition 5 The air inlet and outlet must be at least 50cm away from the wall spacing so as not to affect ...

Page 10: ...t to the stove heater and other equipment will dissipate heat and area with direct sunlight or wind and rain 10 Do place the plug stably and clean the dust on power line 11 Do not damage or modify the power line do not repair by yourself and disassemble or modify the machine 12 Do place the drainage tube smoothly for continuously drain 13 Please shutdown the machine and cut power when in malfuncti...

Page 11: ...place the fuse Poor dehumidification function Filter Clogged Clean the filter Air inlet and outlet blocked Remove obstructions to make good ventilation Windows and doors is not closed Close doors and windows and vents Refrigerant leakage Contact for maintenance Cannot reach suitable humidity level after long time running Doors and windows are not closed Close doors and windows and vents Vapor sour...

Page 12: ... attempt to disassemble the machine to repair without guide 2 When dehumidifier is running or stopping you will hear the sound of refrigeration cycle it is a normal phenomenon not afault 3 Discharge hot air from outlet is a normal phenomenon Ⅷ Maintenance of Machine Do shutdown the machine and cut power before maintenance General maintenance Wipe the body with soft cloth in daily use Use a wet har...

Page 13: ...th Use dust catcher to remove dust or put filter into clean water 40 to wash then place filter back after cleaning P S The filter cannot be put in sunlight directly or roasted to avoid distortion The filter must be placed before power up machine Long time of non use Cut the power or unplug power line to put it in dry and shady place Do notput down the machine to avoid damage and malfunction ...

Page 14: ...g area high 2 6m 350 500 m2 Refrigerant charge R410 3 0Kg Nominal capacity 20kg hour 30 RH80 Working temperature 5 38 C Gross weight 240KGS Net Weight 220KGS Overall dimension 1200 450 1750mm LxWxH It will be not noticed additionally if any change of above parameters please contact with supplier Ⅹ What in the box 1 One Dehumidifier 2 One Instructions For user ...

Reviews: