REPLACING THE BATTERY
Access the battery by removing the product cover. Disconnect and remove battery. Replace battery as previously installed. Battery can be connected in one
direction only, do not force. Allow a minimum 24 hours charging time before carrying out any discharge tests as per the requirements in AS/NZS 2293.
BATTERY LIFE
To maintain the economic life of this product it is required that the battery be discharged and recharged at least once
every 6 months. The battery life can be reduced if the battery is not discharged as per the requirements of AS/NZS 2293
or an equivalent standard. Increasing the number of duration tests above that as defined in AS/NZS 2293 or an equivalent
standard can have a positive effect on the battery performance as long as 12 discharge cycles per year is not exceeded.
The recharging device will operate normally after removal of short circuit fault.
208 mm
350 mm
73 mm
Martec Pty Ltd
6 Austool Pl | Ingleburn, NSW 2565
P: 02 8778 7500
F: 02 8778 7555
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.
PLEASE RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
Tradetec Ceiling LED Emergency Exit Light - Model: TLEEC360
COMPLIANCE
The Emergency Exit has been tested to comply
with relevant Australian
/N
ew
Z
ealand standards.
•
AS/NZS 60598.2.1:2014
•
AS/NZS 60598.1.2011
•
Approval No. GMA-501968
• AS
2293
DIMENSIONS
SAFETY WARNINGS
1. This product must only be installed by a licensed electrician.
2. Before commencing installation turn off and isolate the electrical supply.
3. Risk of accidental contact with live parts. Do not energise with product open or disassembled.
4. Supply voltages within product. Isolate supply voltages before opening or serving or servicing.
5. This luminaire is not intended for use in high-risk task area lighting.
6. Mains supply and battery circuit separated by reinforced insulation.
7. The only user serviceable/replaceable part is the battery pack.
8. Do not attempt to service other parts of the fitting as this will void the warranty.
9. As the installer, it is your responsibility to ensure you comply to all relevant building and safety codes for eg. the BCA, AS3000. Refer to application standards
for the relevant rules.
1 x Li-ion battery