REPLACING THE BATTERY

Access the battery by removing the product cover. Disconnect and remove battery. Replace battery as previously installed. Battery can be connected in one 

direction only, do not force. Allow a minimum 24 hours charging time before carrying out any discharge tests as per the requirements in AS/NZS 2293.

BATTERY LIFE

To maintain the economic life of this product it is required that the battery be discharged and recharged at least once 

every 6 months. The battery life can be reduced if the battery is not discharged as per the requirements of AS/NZS 2293 

or an equivalent standard. Increasing the number of duration tests above that as defined in AS/NZS 2293 or an equivalent 

standard can have a positive effect on the battery performance as long as 12 discharge cycles per year is not exceeded. 

The recharging device will operate normally after removal of short circuit fault.

208 mm

350 mm

73 mm

Martec Pty Ltd

6 Austool Pl | Ingleburn, NSW 2565  

P: 02 8778 7500

F: 02 8778 7555

E: [email protected]

PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. 

PLEASE RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

Tradetec Ceiling LED Emergency Exit Light - Model: TLEEC360

COMPLIANCE

The Emergency Exit has been tested to comply 

with relevant Australian

/N

ew 

Z

ealand standards.

•     

AS/NZS 60598.2.1:2014

•     

AS/NZS 60598.1.2011

•     

Approval No. GMA-501968

•     AS 

2293

DIMENSIONS

SAFETY WARNINGS

1. This product must only be installed by a licensed electrician.

2. Before commencing installation turn off and isolate the electrical supply.

3. Risk of accidental contact with live parts. Do not energise with product open or disassembled.

4. Supply voltages within product. Isolate supply voltages before opening or serving or servicing.

5. This luminaire is not intended for use in high-risk task area lighting.

6. Mains supply and battery circuit separated by reinforced insulation.

7. The only user serviceable/replaceable part is the battery pack.

8. Do not attempt to service other parts of the fitting as this will void the warranty.

9. As the installer, it is your responsibility to ensure you comply to all relevant building and safety codes for eg. the BCA, AS3000. Refer to application standards 

for the relevant rules.