Specifications:
Detection method
Optical
Power Supply
Built-in DC3V Lithium battery (battery not replaceable)
Battery Lifetime
10 years
Monitored area
40 m²
Operating temperature
0 °C - 45 °C
Operating Humidity
< 93 %
Date of replacement
See product label
Individual alarm indicator
Yes
Silence feature (hush mode)
Yes | Hush time: 10±1 minutes
Low battery warning
Yes
Low battery silence facility
installation in leisure
Yes | Hush time: 10 hours
Caravan and Motor Home Suitability No
Mounting Location
Ceiling or wall
Inter-connectable
Yes | max. 40 devices
Wireless frequency
433.42MHz
Wireless distance
Max. 100 metres in free field
Local smoke alarm sound pattern:
ISO 8201 BI 0.5s - pause 0.5s - BI 0.5s - pause 0.5s - BI 0.5s -
pause 1.5s, with the red LED flash, repeat this alarm pattern.
Wireless alarm sound pattern
Beep Beep - pause 1s, with the red LED flash, repeat this alarm
pattern.
Product function description:
Function
Visual Indication
Audio Indication
Normal Alarm Function
The Red LED flashes every 40
seconds.
None
Test (Button Pressed On Direct Unit)
• Test by pressing the TEST button on the smoke alarm
at least 5 seconds.
• The alarm will sound if all electronic circuitry, horn
and battery are working properly. If no alarm sounds,
refer to “Trouble Shooting”.
Flashes once per second for 3
seconds, pauses for 1.5 seconds
then cycles again.
Siren once per second for 3 seconds
then pause 1.5 seconds then cycle
again.
Test (Wireless Paired Unit)
Alarm being tested signals others in the network
Flash twice every 1 second for
duration of 5 minutes.
Beep twice for 10 seconds.
Local Alarm Detected Smoke
Flashes once per second for 3
seconds, pauses for 1.5 seconds
then cycles again.
Siren once per second for 3 seconds
then pause 1.5 seconds then cycle
again.
Paired Wireless Alarm
None
Continuous 2 beeps every 2 seconds.
Silence Feature (Hush Mode)
• This smoke alarm has a built-in Silence feature.
• If cooking or other non-hazardous sources cause
the alarm to sound, it can be temporarily silenced by
pressing the HUSH button for above 2 seconds.
• The alarm enters silence mode for 10 minutes. After
the 10 minute dormant period, the smoke alarm will
resume normal operation.
The Red LED flashes every 8
seconds.
None
Low Battery Warning
Need to replace for a new smoke alarm
The Red LED flashes every 40
seconds.
Beep every 40 seconds.
Connected Low Battery Warning
(Connected device battery is running low)
1 flash every 3 hours.
1 beep every 3 hours.
Low Battery Warning Silence Feature
(Low battery warning is muted)
None
None
Internal Fault Warning
Need to replace smoke alarm
None
Beep every 40 seconds.
Caution:
•
Before using the silence function, identify the source of the smoke and ensure conditions are safe. The unit will resume
normal operation after 10 minute silence.
•
DO not use an open flame to test your alarm, you could damage the alarm or ignite combustible materials and result in a fire.
•
Pull out the yellow tag insulation sheet in battery compartment before installing smoke alarm, or the smoke alarm won’t
work properly.
•
If the alarm sounds, and it is not being tested, it means the unit detected smoke. THE SOUND OF THE ALARM REQUIRES
YOUR IMMEDIATE ATTENTION AND ACTION.