11
Figure 4: Wall mounting smoke alarm
For wall mounting,the connector must
be at the bottom. Ensure “SLIDE TO
REMOVE” arrow on the cover is
pointing upwards (vertical) as shown.
Figure 2:To remove smoke alarm,
slide smoke alarm carefully
away from the base plate to
remove the smoke alarm.
Figure 3: To connect smoke alarm
1. Place smoke alarm in line with the base
plate.
2 Push smoke alarm towards connector
(A). Ensure the smoke alarm slides
fully into the connector.
3 Green AC Power light will come on
when connected to mains.
Installation
• Switch on power and check the green light on alarm cover. It should be lit when mains
power is switched on indicating that the smoke alarm is properly connected to the
mounting base.
• If required, secure Tamper Locking Screw (supplied) to smoke alarm.
• Test alarm by pressing Test button.
A
Installation
• When interconnected, all Smoke Alarms will sound upon activation.
• Warning: This alarm cannot be operated from power derived from a square wave,
or wind derived power sources. These power sources produce high peak voltages that
will damage the alarm.
• Trader recommend that the smoke alarms are installed on their own subcircuit to avoid
false alarms and nuisance chirping that may be caused by electromagnetic
interferences from other electrical equipment.
Mounting Instructions
• The models contain a battery pull tab for your convenience. Tab must be removed to
activate battery backup and provide power to the unit in the event of mains power loss.
• Pull out the battery pull tab.
• If you want to replace the battery, please press the battery reminder tab down into the
battery compartment while inserting the battery. Caution: If the battery reminder tab is
not held down in the battery compartment by the battery, the unit will not attach to the
mounting plate.
• Align and slide smoke alarm up onto mounting base then slide in the reverse direction
of arrow to ensure proper connection.