ASSEMBLY, OPERATION & PREVENTATIVE MAINTENANCE
1.
FEATURES
The TradeQuip 2051T Air Actuated Hydraulic Bottle Jack is designed to operate either manually or pneumatically for lifting
and lowering, but not sustaining load. The manual function allows for normal operation anywhere, even without an air supply.
This unit provides enough lifting power for use with farm vehicles, heavy duty machinery, industrial construction equipment
and more.
2.
BEFORE USE
Conduct a thorough visual inspection checking for any abnormal conditions, such as cracked welds, and damaged, loose, or
missing parts. Bleed any trapped air from the hydraulic system by performing the air bleeding procedure below.
Bleed Air from Hydraulic System:
During transit the unit may become "air-bound", causing a spongy ram action. To bleed the hydraulic system;
1.
Remove the Oil Filler Bung and if required, refill with *32 Grade hydraulic oil until the
oil is lapping the bottom of the Oil Filler Hole then replace the Oil Filler Bung.
2.
Start with the Pump Socket Assembly in the horizontal position and turn the
Release Valve ‘clockwise’ to the lifting position.
3.
With the Jack on its base, pull the Pump Socket upwards to the raised position.
4.
Invert the Jack and push the Pump Socket back to the horizontal position.
5.
Place the Jack back on its base to test the Pump Socket for firmness.
6.
Repeat steps 4 to 6 until the Pump Socket feels firm and the Lift Ram is extending
consistently.
7.
At this point the Pump Assembly should be bled of air.
8.
Follow steps 8 to 9 to bleed the Lift Ram.
9.
Ensure the Jack is back on its base and make sure the Release Valve is in the ‘clockwise’
raise mode, then pump the Pump Socket until the Lift Ram is fully extended.
10.
Invert the Jack and then turn the Release Valve ‘anti-clockwise’ to the lowering position.
Carefully hold the Jack in the inverted position until the Lift Ram is fully retracted. If
necessary apply force to the bottom of the Jack to return the Lift Ram back to fully
retracted position.
At this point both the Manual Pump and Lift Ram should now be free of air and the Jack ready for Air Motor bleeding
(See Below).
Handle
(on Release Valve)
Pump
Socket
Pump
Socket
Saddle
Air
Motor
Oil Filler
Hole
Relief
Valve
Oil Filler Bung
Air
Fitting
Pump
Socket
Lift
Ram
Lift
Ram
Pump
Socket
Pump
Socket
Pump
Socket