2.

 

BEFORE USE 

Prior to each use conduct a visual inspection by checking for abnormal conditions, such as cracked joins and damaged, loose, 

or missing parts. If the supply cord is damaged, it must be replaced by the manufacturer, service agent or similarly qualified 

persons in order to avoid a hazard. 

 

 

Installation of Elbow 

Insert the elbow by aligning the notches in the detachable elbow base on the machine, 

insert and rotate anti clockwise until it locks into place (Fig1). 

 

Installation of Cold Vent Duct

 

Insert the cold vent duct pipe by aligning the notches into the detachable elbow, insert 

and rotate left until it locks in place (Fig1). 

 

 

 

 

Installation of Hot Exhaust Duct 

Insert the hot exhaust duct pipe into the heat vent.  Do not install it in place to guarantee 

stable and firm exhaust pipe (Fig.2). 

 

 

 

 

 

 

 

 

Installation of Extended Hot Exhaust Ducting to Outdoors – (Optional) 

Hot Exhaust discharge air can be removed from the airconditioned space with flexible duct. 

Prior to installation an outlet aperture in the wall is required.   

To connect an extended hot exhaust duct detach the joint of the exhaust outlet and secure 

the ends with a suitable fixing tape. The outdoor heat extraction duct must be water proof 

and protected from external debris falling into the exhaust duct (point pipe downwards). 

 

 

 

 

 

3.

 

OPERATION 

1.

 

Unlock the castors wheels and push the unit using the side handles to a flat, level surface and set the castor brakes to the 

locked position. 

2.

 

Check the prongs and surface of the power cord plug for dust/dirt. If dust and/or dirt are present, wipe off with a clean, 

dry cloth. 

3.

 

Check the power cord, plug and prongs for damage or excess play. 

4.

 

If any damage or excess play is found, contact a qualified repair technician or a qualified electrician to perform 
replacement or repair of the power cord, plug or prongs. Rotate the dial to   or 

 and the compressor immediately 

launches refrigeration. 

5.

 

Start the fan by rotating the control switch to Low   and/or increase the airflow by rotating to High

 . 

6.

 

When the dial is rotated to “0” the appliance is switched off. 

7.

 

When the appliance is running, ensure the filter screen and the cold air ducting are 300mm minimum from the wall or 

other obstacles, and the hot exhaust pipe is 900mm minimum from the ceiling or other obstacles.(Fig12) 

8.

 

Ensure the appliance is on a level, solid surface. 

9.

 

Ensure the filter screen and air outlets are clear of obstacles. 

10.

 

Ensure the hot air exhaust pipe is not pointing towards poor heat resistant items. 

 

 

    

  

WARNING

 – Always turn the machine off before moving – Wait 3minutes before restarting the machine. 

 

Summary of Contents for 1033T

Page 1: ...1033T Made in China to TQB Brands Pty Ltd specifications Visit us at www tqbbrands com au Product Code 1033T AIR CONDITIONER Specifications Cooling Capacity 6 5KW 22200Btu Power Unit 240V 50Hz Rated P...

Page 2: ...w this equipment works Failure to observe any of the instructions contained in the manual could result in severe personal injury to the user or bystanders or cause damage to the equipment and property...

Page 3: ...flammable substances or vapours such as alcohols pesticides gasoline etc DO NOT use the plug to start and to stop the unit Always use the control panel to start and to stop the unit Always turn off t...

Page 4: ...models are equipped standard with heavy duty castors for easy portability TradeQuip Portable Industrial Air Conditioners bring in air from an outside source to cool its condenser cycling hot air to an...

Page 5: ...uitable fixing tape The outdoor heat extraction duct must be water proof and protected from external debris falling into the exhaust duct point pipe downwards 3 OPERATION 1 Unlock the castors wheels a...

Page 6: ...is parallel Rotate the control switch to 0 Empty the water in a resourceful manner and reinstall the condensation tank before restarting Air Conditioner Pipe Drain optional Remove the water tank and...

Page 7: ...r Conditioner is recommended and can be made by an authorised repair facility to ensure that your equipment is in optimum condition and that the equipment has the correct decals and safety labels spec...

Page 8: ...h Pressure Tube 1 10 Tube Head 2 33 Switch Fix Plate 1 56 Compressor 1 11 Hot Air Ring 1 34 Spiral Case Bracket 1 57 Compressor Cushion 3 12 Angle Protection 4 35 Volute Connection Plate 2 58 Pump Bol...

Page 9: ...ed TQB Brands Pty Ltd repair agent This guarantee applies in lieu of any other guarantee expressed or implied and variations of its terms are not authorised Your TQB Brands Pty Ltd guarantee is not ef...

Reviews: