TradeQuip 1032T Owner'S Manual Download Page 3

10/21 

Product Code: 1032T

 

 

 

             

                      Made in China to TQB Brands Pty Ltd specifications 

Page 3 

Visit us at www.tqbbrands.com.au 

STANDARD OPERATING PROCEDURE 

DO NOT 

use this equipment unless you have been trained and assessed to a competent level in its sate use and operation, 

and have been given permission to use this  

 

 

 

 

 

PRE-OPERATIONAL SAFETY CHECKS 

 

Do not use this Air Conditioner in areas that use or store volatile substances (gasoline, kerosene, liquefied gas and other 

volatile liquids; magnesium, aluminium, lead and other volatile dust and/or vapours) to avoid possible ignition, explosion or 

fire. 

 

Servicing must be carried out by a qualified service technician.  Use only TradeQuip identical replacement parts. Use of any 

other parts will void the warranty.  Ensure the Air Conditioner is disconnected from power before servicing. 

 

Use the right product for the job. There are certain applications for which the Air Conditioner was designed. Do not modify 

the Air Conditioner and do not use the Air Conditioner for a purpose for which it was not intended.  

 

Always disconnect the Air Conditioner when moving it from one location to another. 

 

Transport and store the unit in an upright position only. Leave unit in an upright position for at least 3 hours before first use. 

 

Always place the unit on an even, level surface. 

 

Ensure the unit is connected to a grounded power supply of the correct rating / capacity. 

 

The unit will cool when the room temperature is between 18°C (64.4°F) ~ 45°C(113°F) depending on the thermostat setting. 

 

DO NOT use this unit for functions other than those described in this instruction manual. 

 

DO NOT tilt the unit. Only use in the upright position on an even, flat surface. Unit must be positioned at least 600mm from 

the nearest object in any direction 

 

Ensure 240V mains power supply. 

 

Use within temperature range of 18°C ~45°C 

 

This Air Conditioner is intended for indoor use only. 

 

DO NOT cover or obstruct the unit's inlet and outlet grills or ducting. 

 

DO NOT use the unit in areas where it will be exposed to rain or water. 

 

NEVER unplug the unit while it is operating. 

 

DO NOT place any foreign objects on the unit. 

 

DO NOT operate the unit with wet or damp hands. 

 

DO NOT allow chemical substances to come into contact with the unit. 

 

DO NOT operate the unit in the presence of flammable substances or vapours such as alcohols, pesticides, gasoline, etc. DO 

NOT use the plug to start and to stop the unit. Always use the control panel to start and to stop the unit. 

 

Always turn off the unit when it is not in use and unplug the power plug from the electrical outlet. 

 

Always turn the unit off and unplug the main power plug from the electrical outlet before cleaning, moving or performing 

maintenance. 

 

AVOID the use of adaptor plugs or extension cords. If it is necessary to use an extension cord or an adaptor plug to operate 

the unit, ensure that they are correctly rated for the application. Consult a local qualified electrician and all local electrical 

codes to ensure proper setup. Any extension cord used with this device must be rated for a minimum of 30A. 

 

DO NOT unplug the unit by pulling on the electrical cord. Keep electrical cord away from heat sources and always completely 

unroll the cord to avoid overheating. If the power cord becomes damaged, a qualified service agent, qualified electrician, or 

similarly qualified person must replace it, in order to avoid a hazard or shock.  

 

The filters must be used with the product at all times. When the filters are removed for cleaning, always ensure that the unit 

has been turned off and unplugged from the electrical outlet. 

 

DO NOT operate the unit with a damaged power cord or plug, after it malfunctions, has been dropped or damaged. 

 

Regularly clean the filters to maintain efficiency. If the filters are not cleaned regularly, the unit’s output performance and 

efficiency will decline and energy consumption will increase. 

 

Stop operation immediately if abnormal noise or odour is noticed. Contact a local service centre. 

 

This appliance is not to be used by children or persons with reduced physical, sensory or mental capabilities, or lack of 

experience and knowledge, unless they have been given supervision or instruction. 

 

This appliance must be installed in accordance with state and/or national wiring regulations. 

 

If the power supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified electrician 

in order to avoid a hazard. 

 

INTENDED USE 

This appliance is intended for air conditioning industrial or trade workshop/office environments. It is not suitable for any other 

purpose (such as drying clothes, cooling food, etc.)  This product is an Industrial Product and not suitable for household use. 

 

DO NOT tilt the unit 

 

DO NOT operate the unit with wet or damp hands 

Summary of Contents for 1032T

Page 1: ...China to TQB Brands Pty Ltd specifications Visit us at www tqbbrands com au Product Code 1032T AIR CONDITIONER Specifications Cooling Capacity 4 5KW 15300Btu Power Unit 240V 50Hz Rated Power 2000W Ra...

Page 2: ...w this equipment works Failure to observe any of the instructions contained in the manual could result in severe personal injury to the user or bystanders or cause damage to the equipment and property...

Page 3: ...flammable substances or vapours such as alcohols pesticides gasoline etc DO NOT use the plug to start and to stop the unit Always use the control panel to start and to stop the unit Always turn off t...

Page 4: ...models are equipped standard with heavy duty castors for easy portability TradeQuip Portable Industrial Air Conditioners bring in air from an outside source to cool its condenser cycling hot air to an...

Page 5: ...uitable fixing tape The outdoor heat extraction duct must be water proof and protected from external debris falling into the exhaust duct point pipe downwards 3 OPERATION 1 Unlock the castors wheels a...

Page 6: ...switch to 0 Empty the water in a resourceful manner and reinstall the condensation tank before restarting Air Conditioner Condensation water may be discharged directly from the Air Conditioner drain...

Page 7: ...r Conditioner is recommended and can be made by an authorised repair facility to ensure that your equipment is in optimum condition and that the equipment has the correct decals and safety labels spec...

Page 8: ...Control Box 1 53 Muffler 1 10 Tube Head 1 32 Rotate Switch 1 54 High Pressure Tube 1 11 Hot Air Ring 1 33 Switch Fix Plate 1 55 Compressor 1 12 Angle Protection 4 34 Spiral Case Bracket 1 56 Compress...

Page 9: ...ed TQB Brands Pty Ltd repair agent This guarantee applies in lieu of any other guarantee expressed or implied and variations of its terms are not authorised Your TQB Brands Pty Ltd guarantee is not ef...

Reviews: