background image

D. Securites_BSO-EN_v1 08/2017

10

108.2

108.3

108.1

108.1

D.7.  BLOCSTOP BSO fall arrest device

D.7.1. Operation

The safety wire rope passes through a BLOCSTOP™ 

BSO fall arrest device (fig. D1.7). The centrifugal 

weight of the BLOCSTOP™ automatically and conti-

nuously controls the transport speed of the safety wire 

rope through the device. If the speed is too fast, the 

BLOCSTOP™ stops the descent by gripping on the 

safety wire rope.

In an emergency case, the BLOCSTOP™ can be trig-

gered by hand by pressing on the EMERGENCY STOP 

button (108.2) - in particular, in the event of slow 

slip-

page 

of the hoist causing the platform to slope.

D.7.2.  Measures to be taken immediately after 

an incident

Fig. D.7.1 - BLOCSTOP™ BSO

108.1 Lever

108.2 

EMERGENCY STOP button

108.3 

Inspection window

CLOSED

OPEN

OPEN

Fig. D.7.2 – Open the BLOCSTOP™ BSO

The BLOCSTOP™ will engage in the following cases:

A  

Platform lowers with «overspeed»,

B  

Rupture of lifting wire rope or failure of hoist.

In normal operation, the lever (108.1) of the 

BLOCSTOP™ must be in the «OPEN» position (fig. 

D1.7).

Risk of injury by great fall due to 

a safety wire rope which is not 

tensioned between the suspension 

and the BLOCSTOP™. 

If the BLOCSTOP™ is closed when 

the platform is moving up, the 

safety wire rope will not be properly 

tensioned and the BLOCSTOP™ will 

become ineffective.

Case B :

 If the BLOCSTOP™ has engaged subsequent 

to rupture of the lifting wire rope or failure of the hoist:

Evacuate the operator(s).

Secure the equipment by 

appropriate means so that the wire 

rope or hoist can be replaced.

Case A: 

If you can exclude that the lifting wire rope has 

not broken or the hoist has not failed:

1.  Lift the equipment (43) until you have eliminated the 

load on the safety wire rope.

2.  Return the lever (108.1) to the «OPEN» position 

(fig. D.7.2).

3.  Carefully lower the equipment to the ground while 

being ready at all times to press the EMERGENCY 

STOP button (108.2) of the BLOCSTOP™.

4.  Before you continue working, check operation of 

the BLOCSTOP™ as instructed in the following 

pages.

DANGER

DANGER

Summary of Contents for solo 2000

Page 1: ...08 2017 solo 2000 temporary suspended platforms TSP Equipment in accordance with European Union Directives and manufactured per ISO 9001 equipped with TIRAK motor driven hoist original installation a...

Page 2: ...9 D 4 Phase controller 9 D 5 Upper limit switch 9 D 6 Emergency descent 9 D 7 BLOCSTOP BSO fall arrest device 10 E Using the platform 13 E 1 Special safety instructions 13 E 2 Preliminary checks 13 E...

Page 3: ...500 kg 1500 kg The structure must be tested when set into service a coefficient of 1 5 must be applied to the nominal load for the static tests and a coefficient of 1 1 must be applied to the nominal...

Page 4: ...Ps used on non vertical facades TSPs having a non linear installation configuration for example circular platforms Fig B 1 SOLO platform with TIRAK hoist B 2 TSP equipment The equipment covered by thi...

Page 5: ...2 using the lower and upper bolts 4 Close the open side using the remaining lateral guard rail 105 then tighten all the bolts 5 Secure the base of the lower stirrup 104 1 to the floor panel 101 and to...

Page 6: ...in mm2 by conductor 1 TIRAK X 300 Minimal cross sections of wires for TIRAK hoists This concerns cables having a single length with no intermediate connections fully unwound C 2 2 Installation of ele...

Page 7: ...must wear a safety harness and be secured to a sufficiently strong anchor point 1 Bring the platform directly into line with the suspen sions For fastening of the wire ropes to the suspensions refer t...

Page 8: ...ground 6 Wind the length of unused wire rope on the reel C 3 2 Insert the lifting wire rope 1 Connect the power cable to the nearest connector at the bottom of the building 2 Before engaging the lift...

Page 9: ...is indicated by the indicator light 43 in the UP button on the control box To continue working reduce the load in the platform until the indicator light 43 goes off or the platform is cleared from th...

Page 10: ...of lifting wire rope or failure of hoist In normal operation the lever 108 1 of the BLOCSTOP must be in the OPEN position fig D1 7 Risk of injury by great fall due to a safety wire rope which is not...

Page 11: ...ction If the safety wire rope can be pulled upward Do not place the equipment in service Immediately replace the BLOCSTOP If the safety wire rope cannot be pulled upward 1 Return the lever 108 1 to th...

Page 12: ...ace or BLOCSTOP or failed Stop the movement Case 1 the BLOCSTOP is open Manually push the safety wire rope through the BLOCSTOP until it becomes tensioned without releasing it If the ballast weight 11...

Page 13: ...t there are no protruding objects on the building facade which could come into collision with the equipment DANGER DANGER DANGER E 1 Special safety instructions Only wire ropes specified by the TRACTE...

Page 14: ...y in the event of a power failure or to release the upper limit switch The TIRAK hoist is equipped with a manual system which will allow you to lower the platform in the event of a power failure a Swi...

Page 15: ...again to the safety wire rope 10 Wind the length of unused wire rope on the reel E 8 Remove the wire ropes This operation requires two operators one in the platform and the other on the roof The opera...

Page 16: ...ing is worn have it replaced Call in an approved After Sales Service The TIRAK operates for a long period of time in the up direction then stops the motor is hot The motor thermal protection has been...

Page 17: ...ee sign plate on the TIRAK its length its terminations a hook with safety catch and a tip on other hand fig G 3 its construction IMPORTANT DANGER The wire ropes should be replaced if any of the defect...

Page 18: ...he type of motor type and voltage of coil H 3 Electrical control Indicate the electrical diagram number The diagram is located in the control box H 4 BLOCSTOP fall arrest devices In addition to the co...

Page 19: ...to the machinery directive No 2006 42 EC delivered by the notified body BUREAU VERITAS 32 34 rue Rennequin F 75850 PARIS CEDEX 17 France No 0062 The machine also complies with the other following dire...

Reviews: