TRACO POWER TMPS 03 Series Installation Information Download Page 1

 

Sihlbruggstrasse 111 CH-6340 Baar, Switzerland

 

Issued: Dec. 30

th

, 2014 / Rev.:1

 

INSTALLATION 

INFORMATION

 

TMPS 03Series          AC/DC POWER MODULE 

Order Code 

Output Power max.

Output   

TMPS 03-103 

3 Watts 

3.3Vdc / 900mA 

TMPS 03-105 

3 Watts 

5Vdc / 600mA 

TMPS 03-109 

3 Watts 

9Vdc / 333mA 

TMPS 03-112 

3 Watts 

12Vdc / 250mA 

TMPS 03-115 

3 Watts 

15Vdc / 200mA 

TMPS 03-124 

3 Watts 

24Vdc / 125mA 

 

Input Voltage Range: 

85-264VAC / 60-50Hz 

Input Current: 

65mA typ. at Vin = 115VAC 
40mA typ. at Vin = 230VAC 

Operation Temperature Range: 

-25

~+70

 max. 

Terminal for 

Wiring: 

PCB mounting with solder pin’s. 

Output Power Derating: 

+60

℃ to 

+70

 

Î

 0.15W/

Internal Fuse: 

T1A 250VAC Min 

Case Material:  Plastic Resin + Fiberglas 

UL 94V-0 flammability rating 

Safety Instructions: 

¾

  Before installation read these instructions carefully and 

completely. This installation instruction cannot claim for every 
possible example of installation, operation or maintenance. 
Further information’s are obtainable from your local distributor 
office or from the product data sheet which can be downloaded 
from the Internet at http://www.tracopower.com/ 

¾

  The power supplies are constructed in accordance with the 

safety requirements of cUL/UL/IEC/EN60950-1 and 
IEC/EN60335-1. They fulfil the requirements of the Low 
Voltage Directive (LVD) and carries the CE-mark. UL and cUL 
are approved in accordance to UL60950-1, and TUV is 
approved in accordance to IEC/EN60335-1. 

¾

  Before an installation, maintenance or modification work 

ensure that the main switch is switched off and prevented from 
being switched on again. In case of non-observance touching 
at any alive components or improper dealing with this power 
supply can result in death, severe personal injury or substantial 
property damage. The successful and safe operation is 
dependent of proper storage, handling, installation and 
operation. 

¾

  Compliance with the relevant national regulations (in the USA, 

Europe and the other countries) must be observed and 
ensured. Before operation is started the following conditions 
must be ensured: 

ƒ

  Connection to mains supply in compliance with national 

regulations (VDE0100 and EN50178). 

ƒ

  By use of stranded wires, all strands must be fastened in the 

terminal blocks. 

ƒ

  Power supply and mains cables must be sufficiently fused. 

ƒ

  All output wires must be rated for the power supply output 

current and must be connected with the correct polarity. 

ƒ

  Sufficient cooling must be ensured 

ƒ

  Keep away from fire and water

 

¾

 

Never work on the power supply if power is supplied! 

Risk 

of electric arcs and electrical shock which can cause death, 
severe personal injury of substantial property damage.

 

 

 

¾

 

Warning: 

Hazardous voltages and components storing a very 

substantial amount of energy are present in this power supply 
during normal operating conditions. However, these are 
inaccessible. Improper handling may result in an electric shock 
or serious burns! 

¾

  For the assembly information of chosen AC/DC Power Module, 

see the AC/DC Power Module specification and rating label for 
details: 

 

ƒ

  Make sure the dimensions of location for assembly 

complying with category or specification datasheet. 

ƒ

  Do not expose the AC/DC Power Module to excessive heat, 

moisture, dust, or corrosive gases.

 

ƒ

  The overall dimensions of AC/DC Power Module shall be 

assembled according to the ventilation designs of end-use 
product.

 

 

Do not open the power supply until at least 5 minutes after 
it has been disconnected from the mains on all poles. 
 

◆  

Avertissement:

Ce bloc d’alimentation contient une grande 

tension et des composants puissants pendant l’utilisation 
normale. Une mauvaise manipulation peut causer un choc 
électrique ou des brûlures graves ! 

◆  

Pour assembler ce module d’alimentation CA/CC, veuillez 
vous référer aux spécifications et la plaque signalétique du 
module CA/CC : 

 

La dimension de l’endroit de l’assemblage doit correspondre 

à la catégorie ou aux spécifications. 

Il ne faut pas exposer ce module d’alimentation CA/CC à la 

chaleur, à l’humidité, à la poussière ou aux gaz corrosifs. 

La dimension générale du module CA/CC doit respecter le 

système de ventilation du produit fini. 

 

Avant d’ouvrir le bloc d’alimentation, attendre au moins 5 
minutes après la déconnexion de tous les pôles 

 

Reviews: