SP8E Log Splitter
SP8E/0612
Page 17
Routine Maintenance
This chapter describes routine maintenance, i.e. operations carried out by the operator, on the
CAMON SP8E Log Splitter to keep it in perfect working order and therefore reliable for continuous,
long-term use.
All routine maintenance operations must be carried out with the machine off and in the case of
log splitters with electric motor with the power cable disconnected.
$Q\RWKHUPDLQWHQDQFHRSHUDWLRQQRWVSHFL¿FDOO\HQYLVDJHGLQWKLVPDQXDOPXVWEHFDUULHGRXW
by authorised personnel only in that hazardous situations may arise for which the operator is not
prepared.
In the case in which extraordinary maintenance or part replacement operations are not carried
out by authorised personnel, the guarantee shall be immediately null and void and the manufac-
turer shall be relieved of any responsibility for injury to persons or animals or damage.
How to change the hydraulic oil
The spent oil must be replaced with new oil of the type indicated on page 8 (recommended oils)
every 600 hours of operation. To change the oil, proceed as follows.
Make sure that the log pusher is fully retracted.
3ODFHDFROOHFWLRQWUD\DEOHWRKROGDURXQGOLWUHVRIRLOXQGHUWKHRLOGUDLQDJHGRZHO¿JSDJH
8QVFUHZWKHGRZHO¿JZLWKDVXLWDEOHDOOHQZUHQFKDQGOHWDOOWKHRLOLQWKHWDQNGUDLQLQWR
the collection tray.
Tilt the log splitter slightly to drain the oil tank completely.
When the tank is completely empty, clean the drain outlet and cap with petrol, then screw the cap
back into place.
5HPRYHWKHRLOFDSQR¿JSDJHDQG¿OOWKHWDQNZLWKVXLWDEOHRLOWKHRLOVWREHXVHGDUH
indicated on page 8), pouring in about 4.5 litres.
Switch on the Log Splitter and put it into operation, running it through about
1
/
3
of the complete
stroke.
Completely retract the log pusher then add the rest of the oil and put the machine through two
complete cycles to drive the air from the hydraulic circuit.
Routine Maintenance