![TrackingTheWorld AVL300 User Manual Download Page 15](http://html1.mh-extra.com/html/trackingtheworld/avl300/avl300_user-manual_1147239015.webp)
AVL300 User manual
TRACAVL300UM001
- 15
-
3.8.
Ignition Detection
Table 7: Electrical Characteristics of Ignition Detection
Logical State
Electrical State
Active
5.0V to 32V
Inactive
0V to 3V or Open
Figure 10.
Typical Ignition Detection
IGN (Pin3) is used for ignition detection. It is strongly recommended to connect this pin to
ignition key “RUN” position as shown. If you do not connect the ignition detection, not all
functions of the device will be available.
An alternative to connecting to the ignition switch is to find a non permanent power source
that is only available when the vehicle is running. For example the power source for the
FM radio.
IGN signal can be configured to start transmitting information to backend server when
ignition is on; and enter power saving mode when ignition is off.
3.9.
Digital Inputs
There are three general purpose digital inputs on AVL300. They are all negative trigger.
Table 6: Electrical Characteristics of the digital inputs
Logical State
Electrical Characteristics
Active
0V to 0.8V
Inactive
Open