AVL-75 User Manual
For More Information: Please contact TrackingTheWorld, 1633 Bayshore Highway, Suite 390, Burlingame, CA. 94010, USA
Phone: +1.650.692.8100 – Email:
– Website:
www.trackingtheworld.com
Copyright © TrackingTheWorld. All rights reserved. Information in this publication supersedes that in all previously published material. Specification and price
change privileges reserved. All trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies.
TTW-AVL75-UM001
- 14 -
3.6.
UART Interface
There is one UART interface on AVL-75. UART is used for configuration and firmware downloading, and
communicating with external devices like CAN Bus module and RFID reader.
Please note the UART interfaces are all RS232 level. For RS232 level, valid signals are 3V to 15V and -3V
to -15V and the -3V to +3V is not a valid level. 3V to 15V correspond with logic 0 of TTL level, while -3V
to -15V correspond with logic 1.
The examples of connections of UART with female DB-9 and with external devices are showed as
follows.
Figure 7.
The Connection of UART with Female DB-9
Figure 8.
The Connection of UART with External Devices