Tracker IL-TRACKER575S/1 Manual Download Page 13

 

13

Control Panel Menu 

Use the fixture’s Control Panel to access the Control Menu.  The MODE Key moves between 
options, UP/DOWN selects 
the Action of the option and 
ENTER confirms the 
selection. Settings are stored 
and recalled on subsequent 
power cycles. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Start Address 

The Start Address of a fixture is set using the “Addr” mode in the Control Panel Menu.  Consult 
the manual of the system’s DMX512 controller to select a desirable addressing scheme before 
addressing fixtures.  Each fixture connected to the DMX-512 data link requires a Start Address 
to indicate the first DMX channel containing data designated for that fixture, see DMX-512 
Background.  Valid Start Addresses range from 1 to 512.   Fixtures requiring more than one 
channel for control will read subsequent channels up to the total number of channels required.  
A fixture requiring five (5) channels of DMX, set to a Start Address of eleven (11), would read 
data from channels: 11 and 12, 13, 14, 15.   The next logical Start Address would be channel 
16.  Because all fixtures see the same data, fixtures may be set to any address without concern 
to order in the DMX-512 chain or physical location.  Choose a Start Address so the channels 
used do not overlap with other fixtures.  In some cases, it may be desirable to set two or more 
same type fixtures to the same Start Address.  In this case, the fixtures will be slaved together 
and respond to the same data. 
 

Example 

Select Start Addresses for 4 fixtures each requiring 17 channels of DMX.  

Since these are the first fixtures added to the system, the first unit will be set to Start 
Address=1.  This fixture occupies DMX channels 1 thru 17.  The next DMX channel 
available for a Start Address is found by adding the previous fixture’s Start Address to its 
channel requirement: 1+17=18.  DMX channel 18 is the next available Start Address.  In 
this example, to maximize channel usage no empty channels are left between fixtures so 
the second Start Address is set to DMX channel 18. The second fixture occupies DMX 
channels 18 thru 34.  Repeat the process for the remaining two fixtures: 18+17=35 and 
35+17=52.  Therefore, the four 17 channel fixtures have Start Addresses of 1, 18, 35 and 
52. Repeat the technique once more for the first free channel in the system, 52+17=69.  
Channels 69 thru 512 are available for expansion of the system. 

 

Mode

Function

Action

No  = Not Inverted

Yes = Inverted

DMX Start Address

Fixture Reset

Color Wheel 2 Movement Mode

No  = Not Inverted
Yes = Inverted

Selectable 1 to 512

No  = Default

Yes = Initiate Reset
No  = Stepped Change

Yes = Linear Change

Color Wheel 1 Movement Mode

No  = Stepped Change

Yes = Linear Change

Gobo Wheel Movement Mode

No  = Stepped Change

Yes = Linear Change

Lamp ON/OFF

On   = Lamp on

Off   = Lamp off

Working mode 

= DMX-512  mode

= Automatic Demo

Summary of Contents for IL-TRACKER575S/1

Page 1: ...Information specifically for IL TRACKER575S 1 V1 3 This manual contains important information Please read before operating fixture...

Page 2: ...2 2005 Techni Lux Inc...

Page 3: ...he purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux directly to o...

Page 4: ...rol Panel Menu 13 Start Address 13 Example 13 DMX 512 Channels 14 CH 1 4 Pan Tilt Movement 14 CH 5 Movement Speed Pan Tilt 15 CH 6 Control Reset Lamp 15 CH 7 Focus 15 CH 8 Color Wheel 1 16 CH 9 Color...

Page 5: ...obos plus open Gobo wheel with continuous rotation Remote selection of stepped zoom degrees 15 18 22 Motorized focus Motorized iris Variable shutter for strobing effects and quick blackouts Motorized...

Page 6: ...15A Time Delay Slow Size x 1 Control Protocol USITT DMX512 1990 Channels 17 Pan Tilt Resolution16 bit Data I O 3 Pin XLR Cannon Modes Master Slave DMX Optics Reflector High efficiency Dichroic coated...

Page 7: ...arts Front panel 10 Mode button 11 Enter button 12 Up button 13 Down button 14 Display Rear panel 5 Power switch 6 DMX output 7 DMX input 8 Power cord 9 Fuse holder 1 Moving head 2 Yoke 3 Carry handle...

Page 8: ...applied to return items not received in original or incomplete packing Claims Physical damage must be reported to the Freight Carrier or Shipping Company upon receipt of merchandise Damage incurred in...

Page 9: ...matches the power source voltage Consult a qualified electrician if there are any concerns about proper connection to power Pin Cable EU International Brown Light blue ellow Green Y Black White Green...

Page 10: ...the maximum possible life As Discharge lamps age the glass envelope becomes weaker increasing the chance of failure due to the high internal pressures Rupture could result in damage to the fixture an...

Page 11: ...il the projected beam is as evenly bright as possible Mounting Always consult a qualified professional when rigging This fixture may be placed on any flat surface or truss that is capable of safely su...

Page 12: ...positive S A qualified technician can determine if a Data Terminator is needed Adapter 5 to 3 pin Numbers designating each pin can be found on connectors Converting between the two XLR types is done i...

Page 13: ...ore same type fixtures to the same Start Address In this case the fixtures will be slaved together and respond to the same data Example Select Start Addresses for 4 fixtures each requiring 17 channels...

Page 14: ...4 Pan Tilt Movement The Pan and Tilt motors use a position feedback system If the position of either is disturbed the fixture will correct automatically The Pan and Tilt Menu Modes can be used to alt...

Page 15: ...nes between functions and are not values to which the channel should be set In the case of noisy faders or unintentional movement the buffers will prevent slight variations in value to toggle Lamp sta...

Page 16: ...ue Function 0 9 Open 10 19 Open Red 20 29 Red 30 39 Red Yellow 40 49 Yellow 50 59 Yellow Magenta 60 69 Magenta 70 79 Magenta Green 80 89 Green 90 99 Green Orange 100 109 Orange 110 119 Orange Blue 120...

Page 17: ...t Purple Lt Green 104 116 Lt Green 117 129 Lt Green Lt Orange 130 142 Lt Orange 143 155 Lt Orange Blue 156 168 Blue 169 181 Blue Lt Blue 182 194 Lt Blue 195 207 Lt Blue CTO 3200 K 208 220 CTO 3200 K 2...

Page 18: ...4 50 59 Fixed Gobo 5 60 69 Fixed Gobo 6 70 79 Fixed Gobo 7 80 89 Fixed Gobo 8 90 99 Fixed Gobo 9 100 111 Fixed Gobo 1 Vibrate Slow to Fast 112 123 Fixed Gobo 2 Vibrate Slow to Fast 124 135 Fixed Gobo...

Page 19: ...n 0 36 Open 37 73 Rotating Gobo 1 Metal 74 110 Rotating Gobo 2 Metal 111 147 Rotating Gobo 3 Metal 148 184 Rotating Gobo 4 Glass Blue Field Random Dots 185 221 Rotating Gobo 5 Glass Fire Texture Dichr...

Page 20: ...0 15 Beam Angle Focus Correction 171 213 18 Beam Angle Focus Correction 214 255 22 Beam Angle Focus Correction CH 16 Shutter The Shutter functions in three modes Standard Strobe Effect where the shutt...

Page 21: ...21 Photometric Charts...

Page 22: ...the spring and gobo 4 Place the new gobo in the bearing If the gobo is a textured effect install the smooth side toward the lamp If the gobo is a dichroic glass litho install with the coated side away...

Page 23: ...s handled by the controller The physical signals are transmitted using a twisted pair of wires and a common shield a configuration called Balanced The controller and all receiving equipment are connec...

Page 24: ...ements reduce lamp life fixture life and over all performance Before conducting any maintenance disconnect fixture from power mains 1 Disconnect fixture from power mains 2 Use a vacuum with a soft bru...

Page 25: ...units then function correctly issue is programming Bad or end of life lamp Check DMX value for Control Reset Lamp Channel Inspect fixture light path and verify no effects are blocking beam Remove from...

Page 26: ...26 Wiring Diagram stobe 1 stobe 2 Fixation gobo Color wheel B Color wheel A Rotation gobo Rotation gobo wheel Focus Zoom Prism wheel Prism rotation...

Page 27: ...ack 18 SAFETYCABLE4 Safety Cable Silver 18 CA XLR3 1 Pre made 1 3 pin XLR Cable CA XLR3 5 Pre made 5 3 pin XLR Cable CA XLR3 10 Pre made 10 3 pin XLR Cable CA XLR3 20 Pre made 20 3 pin XLR Cable CA XL...

Reviews: