![Tracker Off-Road EViS 2020 Repair And Service Manual Download Page 67](http://html1.mh-extra.com/html/tracker-off-road/evis-2020/evis-2020_repair-and-service-manual_1147189067.webp)
B
ELECTRICAL
Read all of SAFETY and this section before attempting any procedure. Pay particular attention to Notices, Cautions, Warnings and Dangers.
53
Repair and Service Manual
10002660
Testing A Solenoid for Continuity
Put one probe on one of the large terminals and the other
probe on the second large terminal (Ref. Fig. 14).
If the meter shows “0” or gives an audible indication, the
solenoid terminals are “welded” closed and the solenoid
must be replaced.
If the continuity test shows that contacts are not “welded”
and the wiring to the solenoid coil is good, the coil has
failed and the solenoid must be replaced.
Fig. 14 Continuity Check of Solenoid
ACCESORIES
Key Switch
Tool List
Qty.
Screwdriver, Flathead.................................................. 1
Bit Driver...................................................................... 1
Torx Bit, T30 ................................................................ 1
Pliers, Needle Nose..................................................... 1
1.
Set the key switch to the OFF position and remove
the key.
2.
Disconnect the negative (-) battery cable using an
insulated wrench.
3.
Remove the gauge panel (See Gauge Panel
4.
Disconnect the main wiring harness from the key
switch.
5.
Squeeze the tabs on the back side of the key switch
(41) and push it through the front of the gauge panel
(40) (Ref. Fig. 15).
Assemble in the reverse order of removal. Confirm proper
orientation using the alignment pegs.
Fig. 15 Key Switch
State of Charge (SOC) Meter
Tool List
Qty.
Screwdriver, Flathead ..................................................1
Bit Driver ......................................................................1
Torx Bit, T30.................................................................1
Pliers, Needle Nose .....................................................1
1.
Disconnect the negative (-) battery cable.
2.
Remove the gauge panel (See Gauge Panel
3.
Disconnect the main wiring harness from the SOC
meter.
4.
Squeeze the tabs on the back of the SOC meter (42)
and push it through the front of the gauge panel (40)
Assemble in the reverse order of removal. The SOC
meter will only go into the gauge panel in the correct ori-
entation.
Fig. 16 SOC Meter
BEEP
BEEP
40
41
40