Assembly:
DC20/60/110 circuit breaker/disco connects are installed
adjacent to the DC175/250 breakers on the right side panel for SW
systems and on the left side panel for DR systems. Begin the installation
by removing the topmost nut and one flat washer on the back of the circuit
breaker and install the barrel lug over the stud. Replace the flat washer
followed by the starwasher and the nut, then tighten. Insert the breaker in
the side panel from the inside and secure with two 6-32 x 3/8” machine
screws with #6 internal tooth starwashers. When used with the C40
charge controller, connect the C40 Battery (+) terminal to the bottom of the
DCXX and your PV array positive to the barrel lug at the top of the DCXX
to complete the installation. When a charge controller is not used, connect
your PV positive to the top of the breaker, and route a 6 AWG
cable from the bottom of the DCXX to the top of your
DC175/250 breaker.
Tools Required: ¼”, 7/16” & 3/8” socket or wrench; #2
flat-blade screwdriver; wire stripper, crimping tool.
#
Qty
Part No.
Description
1
1
2957
20 amp breaker or
2298
60 amp breaker or
2249
110 amp breaker
2
19”
2323
#6 AWG Red THHN wire used with 20, 60-amp
3302
#2 AWG Red THHN use with 110-amp
3
2
716-1
#6 AWG ring terminal w/ ¼” hole
3300
#2 AWG ring terminal
4
1
1974-1
barrel lug terminal
2
From DC Charging Source
To Battery (+)
DCXX as disconnect between charging source and battery
To Battery (+)
From PV array (+)
To C40 PV (+)
positive terminal
From C40 battery
positive terminal
DCXX as a disconnect for an PV array positive.
2
To Battery (+)
To DC Loads
DCXX as a disconnect between battery positive and load