Parameterization via TRWinProg
TR-Electronic GmbH 2018, All Rights Reserved
Printed in the Federal Republic of Germany
Page 64 of 67
TR-ECE-BA-DGB-0141 v03
03/19/2021
5.6 Speed
5.6.1 Speed
In the online state in the field
Speed 1/min.
the current measuring system speed in
min
-1
is displayed. If the counting direction is inverted by "F/B input (optional)"
(chapter: 4.5) or the "Count direction" function (chapter: 5.1.1, the sign of the speed is
also inverted.
5.6.2 Unit
This selection determines the unit in which the measuring system
Speed
is displayed.
Selection
Description
Default
U/s
Output of the
Speed
in revolutions per second
U/min
Output of the
Speed
in revolutions per minute
X
U/h
Output of the
Speed
in revolutions per hour
5.7 Incremental (optional)
5.7.1 Number of pulses
The parameter defines the output pulses per revolution.
Lower limit
2
Upper limit
65 536
Default
4096
Programmability
1 Step