5.3 Position
5.3.1 Position
In the online state in the field
Position
the current measuring system position is
displayed.
With entering of a value into the field
Position
the measuring system can be
adjusted on the desired position value. The new position is set if the function
Data
write to device
is executed.
Origin Type
desired position value
< programmed Total number of steps
5.4 Cams
5.4.1 Cams on/off
Under
"Cams on/off"
the switch-on and switch-off points of the four possible limit
switches are adjusted. The limit switches can be output in the form of special bits on
the SSI interface,
see chapter “SSI special bit”.
lower limit
–1 073 741 824
upper limit
1 073 741 823
default
0
Cam as limit switch
5.4.2 Overspeed 1/min
Under
"Overspeed 1/min"
the allowed maximum speed of the speed monitor is
adjusted. The maximum speed must be between 10 and 6000 min
-1
, the default
setting is 6000 min
-1
. The speed monitor can be output in the form of special bits on
the SSI interface, see chapter “SSI special bit”.
lower limit
10
upper limit
6000
default
6000