Causes of faults and remedies
TR-Electronic GmbH 2016, All Rights Reserved
Printed in the Federal Republic of Germany
Page 126 of 127
TR - ECE - BA - DGB - 0128 - 01
11/20/2018
11.2 Emergency Error codes
Emergency objects are triggered by the occurrence of a device internal error situation,
transmission format see chapter “Emergency Message”, page 123.
The error indication is carried out about the objects
-
Error register 1001h, page 108 and
-
Pre-defined error field 1003h, page 109
11.2.1 Object 1001h: Error register
The error register displays bit coded the error state of the measuring system. Also
several errors at the same time can be displayed by a set bit. The error code of the
error occurred last is stored in object 1003h, sub-index 1, the number of errors in sub-
index 0. An error is signaled at the moment of the occurrence by an EMCY-message.
By reading of the object 1001h the error stored last in object 1003h, sub-index 0, is
cleared. Each further read request clears a further error from the list. With the clearing
of the last error the error register is set back and an EMCY-message with error code
"0x000" is transferred.
Bit
Meaning
0
generic error
1
0
2
0
3
0
4
communication error (overrun, error state)
5
0
6
0
7
0