Printed in the Federal Republic of Germany
TR-Electronic GmbH 2016, All Rights Reserved
11/20/2018
TR - ECE - BA - DGB - 0128 - 01
Page 123 of 127
9 Emergency Message
Emergency messages are triggered by the occurrence of a device internal malfunction
and are transmitted from the concerned application device to the other devices with
highest priority.
Emergency Message
Byte
0
1
2
3
4
5
6
7
Contents
Emergency
Error Code
Object 1003h,
Byte 0-1
Error
Register
Object
1001h
0
0
0
0
0
COB-Identifier = 080h + Node-ID
If the measuring system detects an internal error, an emergency message will be
transmitted with the error code of
“Object 1003h: Pre-defined error field” and “Object
”.
If the error disappears, the measuring system transmits an emergency message with
error code "0" (reset error / no error) and error register "0".