Parameterization
TR-Electronic GmbH 2016, All Rights Reserved
Printed in the Federal Republic of Germany
Page 122 of 127
TR - ECE - BA - DGB - 0128 - 01
11/20/2018
8.3.5.5 Object 6506h: Supported warnings
This object is not supported.
By read access the value is always "0".
8.3.5.6 Object 6507h: Profile and software version
This object contains in the 1st 16 bits the profile version which is implemented in the
measuring system. It is combined to a revision number and an index.
Profile version:
03.02 dec.
Binary code:
0000 0011 0000 0010
Hexadecimal:
03
02
The 2nd 16 bits contain the software version which is implemented in the measuring
system. Only the last 4 digits are available.
Software version: 01.01 dec.
Binary code:
0000 0001 0000 0001
Hexadecimal:
01
01
The complete software version is contained in object 100Ah, see page 110.
Unsigned32
Profile version
Software version
Byte 0
Byte 1
Byte 2
Byte 3
2
7
to 2
0
2
15
to 2
8
2
7
to 2
0
2
15
to 2
8
8.3.5.7 Object 6508h: Operating time
This object is not supported.
By read access the value is always "0".
8.3.5.8 Object 6509h: Offset value
This object contains the offset value calculated by the preset function. The offset value
is stored and can be read from the measuring system.
8.3.5.9 Object 650Ah: Manufacturer offset value
This object is not supported.
By read access the value is always "0".
8.3.5.10 Object 650Bh: Serial number
This object contains the current Serial-No. of the device and corresponds to the
Identity-Object 1018h, Sub-index 4.