TQC TE1005 Instruction Manual Download Page 2

 

 

Relative humidity 

10%~90%RH operating,    <80%RH storage 

Power supply 

9V battery, NEDA 1604A or IEC 6LR61. 

Weigth 290g. 
Dimensions 

100 x 56 x 230mm. 

 

z

 

Infrared thermometer specifications 

 

Range (auto. selection 0.1°C/1°C) 

Resolution 

Accuracy 

-50.0°C to -20.0°C 

± 5°C; 

-50.0°C to 200.0°C 

-20.0°C to 200.0°C 

0.1°C 

± 1.5% of reading ± 2°C; 

201°C to 538°C 

± 2% of reading ± 2°C; 

539°C to 750°C 

1°C 

± 3.5% of reading ± 5°C. 

 
 

Range(auto. selection 0.1°F/1°F 

Resolution 

Accuracy 

-58.0°F to -4.0°F 

± 9°F; 

-58.0°F to 200.0°F 

-4.0°F to 200.0°F 

0.1°F 

± 1.5% of reading ± 4°F; 

201°F to 1000°F 

± 2% of reading ±°F; 

1001°F to 1382°F   

1°F 

± 3.5% of reading ±9°F. 

 
Note: 

Accuracy is given at 18 oC to 28 oC (64 oF to 82 oF), less than 80 % RH.

 

Field of View: 

Make sure that the target is larger than the unit’s spot size. The smaller the target, the closer you should be to it. When accuracy is critical, make 
sure the target is at least twice as large as the spot size. 

Emissivity:

 

0.95 fixed value 

 
3.

 

FRONT PANEL DESCRIPTION 

    IR sensor                                     

  Laser pointer beam 

  LCD Display  

   

°

F select key 

   

 select key 

  Backlight select key 

  Laser select key 

⑧ 

Measurement Trigger 

⑨ 

Handle Grip 

⑩ 

Battery Cover 

 
4.

 

INDICATOR 

  Digital readout                    

  Temperature 

 (Celsius) 

  Temperature 

 (Fahrenheit) 

  Measuring indication 

    Data Hold       

  LOW battery indicator 

  Laser Point  

⑧ 

Fixed emissivity (0.95) 

 

1
2
3

6

5

4

7

8

+

9

5

6

3

10

4

8

7

-

¡ ã

F

HOLD

¡ ã

C

SCAN

1

2

Summary of Contents for TE1005

Page 1: ...m enter your eye another person s eye or the eye of an animal z Be careful no to let the beam on a reflective surface strike your eye z Do not allow the laser light beam impinge on any gas which can explode 2 SPECIFICATIES z General specifications Display 3 digital LCD screen with backlight Measuring range resolution 50 0 C to 750 C 58 0 F to 1382 F 0 1 C to 200 1 over 200 Response time Less than ...

Page 2: ...01 F to 1382 F 1 F 3 5 of reading 9 F Note Accuracy is given at 18 oC to 28 oC 64 oF to 82 oF less than 80 RH Field of View Make sure that the target is larger than the unit s spot size The smaller the target the closer you should be to it When accuracy is critical make sure the target is at least twice as large as the spot size Emissivity 0 95 fixed value 3 FRONT PANEL DESCRIPTION IR sensor Laser...

Page 3: ...ent temperatures are to be measured followed by high temperature measurements some time several minutes is required after the low and before the high temperature measurements are made This is a result of the cooling process which must take place for the IR sensor 6 BATTERY REPLACEMENT As battery power is not sufficient LCD will display replacement with one new battery type 9V is required Open batt...

Page 4: ...black 0 94 Snow 0 83 Plastic 0 85 to 0 95 Glass 0 90 to 0 95 Timber 0 90 Ceramic 0 90 to 0 94 Paper 0 70 to 0 94 Marble 0 94 Chromium oxides 0 81 Plaster 0 80 to 0 90 Copper oxides 0 78 Mortar 0 89 to 0 91 Iron oxides 0 78 to 0 82 Brick 0 93 to 0 96 Textiles 0 90 8 DISCLAIMER The information given in this manual is not intended to be exhaustive and any person using the product for any purpose othe...

Reviews: