Relative humidity
10%~90%RH operating, <80%RH storage
Power supply
9V battery, NEDA 1604A or IEC 6LR61.
Weigth 290g.
Dimensions
100 x 56 x 230mm.
z
Infrared thermometer specifications
Range (auto. selection 0.1°C/1°C)
Resolution
Accuracy
-50.0°C to -20.0°C
± 5°C;
-50.0°C to 200.0°C
-20.0°C to 200.0°C
0.1°C
± 1.5% of reading ± 2°C;
201°C to 538°C
± 2% of reading ± 2°C;
539°C to 750°C
1°C
± 3.5% of reading ± 5°C.
Range(auto. selection 0.1°F/1°F
Resolution
Accuracy
-58.0°F to -4.0°F
± 9°F;
-58.0°F to 200.0°F
-4.0°F to 200.0°F
0.1°F
± 1.5% of reading ± 4°F;
201°F to 1000°F
± 2% of reading ±°F;
1001°F to 1382°F
1°F
± 3.5% of reading ±9°F.
Note:
Accuracy is given at 18 oC to 28 oC (64 oF to 82 oF), less than 80 % RH.
Field of View:
Make sure that the target is larger than the unit’s spot size. The smaller the target, the closer you should be to it. When accuracy is critical, make
sure the target is at least twice as large as the spot size.
Emissivity:
0.95 fixed value
3.
FRONT PANEL DESCRIPTION
①
IR sensor
②
Laser pointer beam
③
LCD Display
④
°
F select key
⑤
℃
select key
⑥
Backlight select key
⑦
Laser select key
⑧
Measurement Trigger
⑨
Handle Grip
⑩
Battery Cover
4.
INDICATOR
①
Digital readout
②
Temperature
℃
(Celsius)
③
Temperature
℉
(Fahrenheit)
④
Measuring indication
⑤
Data Hold
⑥
LOW battery indicator
⑦
Laser Point
⑧
Fixed emissivity (0.95)
1
2
3
6
5
4
7
8
+
9
5
6
3
10
4
8
7
-
¡ ã
F
HOLD
¡ ã
C
SCAN
1
2