background image

05/20 

Product Code: 1033T 

 

             

                      Made in China to TQB Brands Pty Ltd specifications 

Page 3 

Visit us at www.tqbbrands.com.au 

STANDARD OPERATING PROCEDURE 

DO NOT use this equipment unless you have been trained and assessed to a competent level in its sate use and operation, 
and have been given permission to use this  

 

 

 
PRE-OPERATIONAL SAFETY CHECKS 
 

 

Do  not  use  this Air Conditioner in areas that use or store volatile  substances (gasoline, kerosene, liquefied gas and other 
volatile liquids; magnesium, aluminium, lead and other volatile dust and/or vapours) to avoid possible ignition, explosion or 
fire. 

 

Servicing must be carried out by a qualified service technician.  Use only TradeQuip identical replacement parts. Use of any 
other parts will void the warranty.  Ensure the Air Conditioner is disconnected from power before servicing. 

 

Use the right product for the job. There are certain applications for which the Air Conditioner was designed. Do not modify 
the Air Conditioner and do not use the Air Conditioner for a purpose for which it was not intended.  

 

Always disconnect the Air Conditioner when moving it from one location to another. 

 

Transport and store the unit in an upright position only. Leave unit in an upright position for at least 3 hours before first use. 

 

Always place the unit on an even, level surface. 

 

Ensure the unit is connected to a grounded power supply of the correct rating / capacity. 

 

The unit will cool when the room temperature is between 18°C (64.4°F) ~ 45°C(113°F) depending on the thermostat setting. 

 

DO NOT use this unit for functions other than those described in this instruction manual. 

 

DO NOT tilt the unit. Only use in the upright position on an even, flat surface. Unit must be positioned at least 600mm from 
the nearest object in any direction 

 

Ensure 240V mains power supply. 

 

Use within temperature range of 18°C ~45°C 

 

This Air Conditioner is intended for indoor use only. 

 

DO NOT cover or obstruct the unit's inlet and outlet grills or ducting. 

 

DO NOT use the unit in areas where it will be exposed to rain or water. 

 

NEVER unplug the unit while it is operating. 

 

DO NOT place any foreign objects on the unit. 

 

DO NOT operate the unit with wet or damp hands. 

 

DO NOT allow chemical substances to come into contact with the unit. 

 

DO NOT operate the unit in the presence of flammable substances or vapours such as alcohols, pesticides, gasoline, etc. DO 
NOT use the plug to start and to stop the unit. Always use the control panel to start and to stop the unit. 

 

Always turn off the unit when it is not in use and unplug the power plug from the electrical outlet. 

 

Always turn the unit off and unplug the main power plug from the electrical outlet before cleaning, moving or performing 
maintenance. 

 

AVOID the use of adaptor plugs or extension cords. If it is necessary to use an extension cord or an adaptor plug to operate 
the unit, ensure that they are correctly rated for the application. Consult a local qualified electrician and all local electrical 
codes to ensure proper setup. Any extension cord used with this device must be rated for a minimum of 30A. 

 

DO NOT unplug the unit by pulling on the electrical cord. Keep electrical cord away from heat sources and always completely 
unroll the cord to avoid overheating. If the power cord becomes damaged, a qualified service agent, qualified electrician, or 
similarly qualified person must replace it, in order to avoid a hazard or shock.  

 

The filters must be used with the product at all times. When the filters are removed for cleaning, always ensure that the unit 
has been turned off and unplugged from the electrical outlet. 

 

DO NOT operate the unit with a damaged power cord or plug, after it malfunctions, has been dropped or damaged. 

 

Regularly clean the filters to maintain efficiency. If the filters are not cleaned regularly, the unit’s output performance and 
efficiency will decline and energy consumption will increase. 

 

Stop operation immediately if abnormal noise or odour is noticed. Contact a local service centre. 

 

This  appliance  is  not  to  be  used  by  children  or  persons  with  reduced  physical,  sensory  or  mental  capabilities,  or  lack  of 
experience and knowledge, unless they have been given supervision or instruction. 

 

This appliance must be installed in accordance with state and/or national wiring regulations. 

 

If the power supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified electrician 
in order to avoid a hazard. 

 

 

INTENDED USE 
This appliance is intended for air conditioning industrial or trade workshop/office environments. It is not suitable for any other 
purpose (such as drying clothes, cooling food, etc.)   

 

DO NOT tilt the unit 

 

DO NOT operate the unit with wet or 
damp hands 

Summary of Contents for TradeQuip 1033T

Page 1: ... 1033T Made in China to TQB Brands Pty Ltd specifications Visit us at www tqbbrands com au Product Code 1033T AIR CONDITIONER Specifications Cooling Capacity 6 5KW 22200Btu Power Unit 240V 50Hz Rated Power 3000W Rated Current 13 5A Max Air Flow 1200m3 per hour Noise Level 65dB A Operating Temperature 18 45 C Suction Pressure 2 5Mpa Max Discharge Pressure 4 5Mpa Max Speed Control 2 speed Refrigeran...

Page 2: ...ow this equipment works Failure to observe any of the instructions contained in the manual could result in severe personal injury to the user or bystanders or cause damage to the equipment and property Keep this manual in a convenient and safe place for future reference Whilst every effort has been made to ensure accuracy of information contained in this manual the TQB Brands Pty Ltd policy of con...

Page 3: ...T operate the unit in the presence of flammable substances or vapours such as alcohols pesticides gasoline etc DO NOT use the plug to start and to stop the unit Always use the control panel to start and to stop the unit Always turn off the unit when it is not in use and unplug the power plug from the electrical outlet Always turn the unit off and unplug the main power plug from the electrical outl...

Page 4: ... models are equipped standard with heavy duty castors for easy portability TradeQuip Portable Industrial Air Conditioners bring in air from an outside source to cool its condenser cycling hot air to an outside source This provides a fresh cool air room temperature with high efficiency Just wheel it in plug it in and it goes to work immediately giving high cooling capacity to help wherever and at w...

Page 5: ...suitable fixing tape The outdoor heat extraction duct must be water proof and protected from external debris falling into the exhaust duct point pipe downwards 3 OPERATION 1 Unlock the castors wheels and push the unit using the side handles to a flat level surface and set the castor brakes to the locked position 2 Check the prongs and surface of the power cord plug for dust dirt If dust and or dir...

Page 6: ...pty the water in a resourceful manner and reinstall the condensation tank before restarting Air Conditioner Pipe Drain optional Condensation water may be discharged directly from the Air Conditioner drain pipe Remove the water tank and empty push the optional drain pipe on to the appliance outlet inside the tank recess Then locate the drain pipe through the round hole in the corresponding side pla...

Page 7: ...ir Conditioner is recommended and can be made by an authorised repair facility to ensure that your equipment is in optimum condition and that the equipment has the correct decals and safety labels specified by the manufacturer TROUBLESHOOTING Out of Operation Power Cable loose Fuse is burnt Insert Power Cable into power supply Repair or replace fuse Out of Operation Heat exchange surface is blocke...

Page 8: ...gh Pressure Tube 1 10 Tube Head 2 33 Switch Fix Plate 1 56 Compressor 1 11 Hot Air Ring 1 34 Spiral Case Bracket 1 57 Compressor Cushion 3 12 Angle Protection 4 35 Volute Connection Plate 2 58 Pump Bolt 3 13 Front Shell 1 36 Cold Inlet Tube Assy 1 59 Hot Air Motor Support 1 14 Filter Net 1 37 Lower Motor 1 60 Anterior Spiral Case 1 15 Control Cover Plate 1 38 Spiral Case Fixed Frame 2 61 Wind Mill...

Page 9: ...sed TQB Brands Pty Ltd repair agent This guarantee applies in lieu of any other guarantee expressed or implied and variations of its terms are not authorised Your TQB Brands Pty Ltd guarantee is not effective unless you can produce upon request a dated receipt or invoice to verify your proof of purchase within the 12month period Consumer Guarantee Our goods come with a guarantee that cannot be exc...

Reviews: