Safety Guidelines 

Use the following safety guidelines to protect your MBox-R/-V/-VH-E39 from potential damage and ensure your personal safety. 

If the following safety guidelines are not observed, it could lead to injuries to the operator and/or damage of the MBox-R/-V/-VH-

E39. 

In cases of non-observance of the safety guidelines TQ-Systems GmbH is exempt from accident liability, even if the MBox-R/-V/-

VH-E39 is still under warranty. The MBox-R/-V/-VH-E39 must be used as specified in this User's Guide, which describes the safety 

guidelines for the MBox-R/-V/-VH-E39 as well as for the operator. The place where the MBox-R/-V/-VH-E39 is installed has to meet 

the requirements of the country's standards and regulations. If power cables are delivered with the MBox-R/-V/-VH-E39 only 

these may be used. Ensure that there is sufficient air circulation to cool the MBox-R/-V/-VH-E39. Do not cover the MBox-R/-V/-VH-

E39 or mount it close to heat sources or damp places. 

To completely disconnect the MBox-R/-V/-VH-E39 from mains, the power cord has to be disconnected. Make sure the power cord 

is always easy accessible. Only open the MBox-R/-V/-VH-E39 after all cables are disconnected from the MBox-R/-V/-VH-E39 to 

insert or remove add-on cards. 
This may only be done by qualified personnel. If add-on cards are installed in the MBox-R/-V/-VH-E39, all effective legal 

regulations and all technical data has to be adhered to. It has to be ensured, that the power consumption of add-on cards does 

not exceed the limitations and the current consumption specified on the label of the MBox-R/-V/-VH-E39. Very important! A safe 

operation is not possible when the MBox-R/-V/-VH-E39 is visibly damaged or is not functioning at all. In this case the MBox-R/-V/-

VH-E39 must be switched off and it must be ensured that the MBox-R/-V/-VH-E39 cannot be put back into operation. It is very 

important to ensure that the wires of power cords are sufficiently dimensioned, according to the maximum electrical 

specifications of the MBox-R/-V/-VH-E39. Standards and regulations like EN62368-1, VDE0100, EN60204, or UL508 have to be 

adhered to. This information helps you to safely use the MBox-R/-V/-VH-E39. 

Follow and keep all information included with the MBox-R/-V/-VH-E39. The information in this User's Guide does not alter the 

terms of your purchase agreement or the TQ-Systems GmbH Limited Warranty. Your safety is important to us. The MBox-R/-V/-

VH-E39 is developed to be safe and effective. Power cords, power adapters, and other features can create potential safety risks 

that may result in physical injury or property damage, especially if misused. To reduce these risks, follow the instructions in this 

User's Guide, and observe all warnings on the MBox-R/-V/-VH-E39 and in this User's Guide. By carefully following the information 
contained in this User's Guide and provided with the MBox-R/-V/-VH-E39, you can help protect yourself from hazards and create 

a safer environment. 

Do not attempt to service the MBox-R/-V/-VH-E39 yourself unless instructed to do so by TQ-Systems GmbH or this User's Guide. 

 

1.8

 

Grounding Considerations 

Be aware, that the chassis of the MBox-R/-V/-VH-E39 is internally connected to Digital Ground (Power Supply Connector GND).  

Depending on the Power Supply Unit used, it also might be connected or not to protective earth (PE).  

This has to be considered, when connecting other components to the MBox-R/-V/-VH-E39.  

The grounding of the MBox-R/-V/-VH-E39 might also influence the electromagnetic emission of the MBox-R/-V/-VH-E39.  

TQ-Systems GmbH recommends using the CINCON TRG70A power supply unit or equivalent, where PE is connected to GND. 

 

1.9

 

ESD Considerations 

To avoid damaging the MBox-R/-V/-VH-E39 caused by ESD make sure the following measures are adhered to: 
Ground your workplace with e.g. anti-static mats and ground yourself with a wrist strap. Only use conductive tools when working 

on the MBox-R/-V/-VH-E39. Always handle electrostatic sensitive components at their edges, preferably wear conductive gloves. 

Remove the power cord from the MBox-R/-V/-VH-E39 before inserting or removing connectors or before inserting or removing 

add-on cards. Don’t touch the contacts of connectors. Keep you work environment tidy and free of non-conductive materials. 

 

1.10

 

Handling the MBox-R/-V/-VH-E39 

Attention: Handling the MBox-R/-V/-VH-E39 

 

Improper or incorrect handling of the MBox-R/-V/-VH-E39 can substantially reduce its life span. TQ-
Systems GmbH cannot be held responsible for unauthorized modifications made by the user and the 

consequences thereof, which may alter the conformity of the MBox-R/-V/-VH-E39. 

 

1.11

 

Coin Cell Battery 

Attention: Coin cell battery 

 

Danger of explosion if the coin cell battery is incorrectly replaced. Replace the coin cell battery only 

with a coin cell battery of the same type and size. Check for correct polarity before inserting the coin 
cell battery in its socket. Do not immerse into water, heat to more than +100 °C, repair or disassemble 

the coin cell battery. Dispose the coin cell battery as required by local ordinances or regulations. 

Summary of Contents for MBox-R-E39

Page 1: ...User s Guide l MBox R V VH E39 UG 0100 l 2021 TQ Group Page I MBox R V VH E39 User s Guide MBox R V VH E39 UG 0100 2021 05 25...

Page 2: ...Characteristics 7 4 1 2 Power Consumption Specification 7 4 2 Environmental Specification 7 4 3 Connectors and Interfaces 8 4 3 1 External Connectors and Interfaces Arrangement 8 4 3 1 1 Power Supply...

Page 3: ...R E39 Rear 9 Figure 4 MBox V E39 Rear also valid for MBox VH E39 9 Figure 5 DC Power Supply Connector 10 Figure 6 Mini DP Connector 10 Figure 7 RJ45 Connectors 10 Figure 8 D Sub 9 Adapter Cable 12 Fig...

Page 4: ...you start working with the MBox R V VH E39 This User s Guide provides information which is essential for proper operation of the MBox R V VH E39 General safety instructions must be adhered to and only...

Page 5: ...The MBox R V VH E39 is developed to be safe and effective Power cords power adapters and other features can create potential safety risks that may result in physical injury or property damage especial...

Page 6: ...e should conclude that brand and trademarks are rightly protected by a third party 2 3 Disclaimer TQ Systems GmbH does not guarantee that the information in this User s Guide is up to date correct com...

Page 7: ...R E39 refers to the MBox with a robust housing The MBox R comes in one height with or without serial ports The name MBox V E39 refers to the MBox with a variable housing The MBox V is available in two...

Page 8: ...figurations and individual branding For this reason several other TQMxE39M modules are available on request Table 4 TQMxE39M Module Versions Module CPU Graphics TPM DDR3L SDRAM eMMC Temperature Module...

Page 9: ...MLC Standard Temp 0 C to 70 C 32 64 128 256 512 Gbyte mSATA SATA III MLC Extended Temp 40 C to 85 C Other mSATA flash drives on request Add ons On request e g o WiFi Extended Temp 40 C to 85 C ZigBee...

Page 10: ...red with enough reserve When selecting the power supply the maximum power consumption of all components must be taken into account 4 2 Environmental Specification The following temperature parameters...

Page 11: ...MBox R E39 Front with D Sub 9 Connectors VH version has two additional Sub D connectors Figure 2 MBox V E39 Front without D Sub 9 Connectors MBox VH E39 2 Ethernet 2 Mini DisplayPort Port B with DP su...

Page 12: ...es Arrangement continued Holes for SMA connectors are not supported in standard versions unless otherwise specified Figure 3 MBox R E39 Rear Figure 4 MBox V E39 Rear also valid for MBox VH E39 Antenna...

Page 13: ...it is possible to connect monitors with DP DVI HDMI and VGA input by using dedicated cables and adapters The actual configuration with the Intel Atom E3900 series has extended monitor support with re...

Page 14: ...utton and the Reset Button on the rear side of the MBox R V VH E39 provide the following functions Table 8 Power Button and Reset Button Functions Status Event System response No power supply connecte...

Page 15: ...formation refer to chapter 3 2 and 4 3 2 5 MBox V E39 and MBox VH E39 housings have the holes for SMA connectors as standard 4 3 2 3 Other Optional Connectors For individual solutions more optional co...

Page 16: ...MBox R V VH E39 UG 0100 l 2021 TQ Group Page 13 5 MECHANICS 5 1 Dimensions The following illustrations show the MBox R E39 Figure 10 MBox R E39 Dimensions mm Front View Figure 11 MBox R E39 Dimension...

Page 17: ...ns continued Figure 12 MBox V E39 without D Sub 9 Connectors Dimensions mm Bottom View Figure 13 MBox VH E39 with D Sub 9 Connectors Dimensions mm Bottom View The full height of the housing incl cooli...

Page 18: ...ional clamp for MBox V E39 and MBox VH E39 Directly with screws Please contact support tq group com for more details or ideas suitable for your application Figure 14 MBox R E39 Mounting Dimensions mm...

Page 19: ...ironments IEC 62368 1 2018 Audio video information and communication technology equipment Part 1 Safety requirements 7 WEEE AND RECYCLING 7 1 WEEE TQ Systems GmbH encourages owners to recycle their MB...

Page 20: ...TQ Systems GmbH M hlstra e 2 l Gut Delling l 82229 Seefeld info tq group com l www tq group com...