TROUBLESHOOTING 

Problem 

Symptom 

Cause 

Conclusion 

Solution 

Jack will not 

lift using 

manual 

pump 

Manual pump has 

no resistance, lift 

ram will not raise 

Release valve not 

tightly closed 

 

 

Air in hydraulic system 

 

 

Load weight exceeds 

lift capacity  

 

Overload actuated 

 

 

Bypass through release 

valve  

 

 

Air cavitation in pump 

and/or lift ram 

 

Higher capacity jack 

required 

 

Relief valve needs reset 

 

 

Ensure release valve 

tightly closed 

 

 

Bleed system 

 

 

Select higher 

capacity jack 

 

Contact qualified 

technician for repairs 

 

Jack Will Not 

Lift using Air 

pump 

 

 

 

Air Pump operating 

but lift ram will not 

raise 

 

 

Release valve not 

tightly closed 

 

 

Air in hydraulic system 

 

 

Load weight exceeds 

lift capacity  

 

Overload actuated 

 

 

 

Air Motor effected by 

water in air supply.          

Air exhausting but 

motor not pumping. 

 

 

 

 

Bypass through release 

valve  

 

 

Air cavitation in pump 

and/or lift ram 

 

Higher capacity jack 

required 

 

Relief valve needs reset 

 

 

 

Lubrication flushed out of 

air motor, requires added 

lubrication. 

 

Adding lubrication to air 

motor fails to remedy 

issue. 

Ensure release valve 

tightly closed 

 

 

Bleed system 

 

 

Select higher 

capacity jack 

 

Contact qualified 

technician for repairs 

 

Install air /water 

separator to air 

supply.                

 

Follow Lubrication 

instructions. 

Jack will not 

hold load 

 

Load cannot be 

sustained, lift ram 

drops under load 

 

Pump handle rises 

Release valve not 

tightly closed 

 

 

Damaged main seal 

 

Main check valve 

obstructed 

Bypass through release 

valve 

 

 

Replace main ram seals 

 

Replace main check valve 

ball and reseat valve seat 

 

Ensure release valve 

tightly closed 

 

 

 

Contact qualified 

technician for repairs 

 

Jack will not 

lower after 

unloading 

Ram rises after 

retracting 

 

 

Release valve pin 

seized 

Reservoir overfilled 

 

 

 

Linkages binding 

Pump failure due to 

cavitation caused by 

excess reservoir level 

 

Dry release valve pin 

Drain fluid to proper 

level 

 

 

Lubricate release 

valve with 32grade 

hydraulic oil 

 

Summary of Contents for PROBJ30TA

Page 1: ...UATED About the TQ Pro brand TQ Pro top quality Tools and Equipment are designed and manufactured for specialist professional use in a garage and workshop environment TQ Pro products are strong reliab...

Page 2: ...convenient and safe place for future reference Whilst every effort has been made to ensure accuracy of information contained in this manual the TQ Pro policy of continuous improvement determines the...

Page 3: ...e this jack for any purpose other than specified by this owner s manual Do not modify this jack and do not use this jack for a purpose for which it was not intended POTENTIAL HAZARDS User does not rea...

Page 4: ...ace the Oil Filler Bung 2 Start with the Pump Socket Assembly in the horizontal position and turn the Release Valve clockwise to the lifting position 3 With the Jack on its base pull the Pump Socket u...

Page 5: ...Jack ready for Operation If the Jack continues to show the Symptoms as above please refer to a Qualified Hydraulic Technician 3 OPERATION Prior to each use always conduct a visual inspection checking...

Page 6: ...prevent rust Periodically check the pump piston and ram for signs of rust or corrosion Clean as needed and wipe with an oily cloth NEVER USE SANDPAPER OR ABRASIVE MATERIAL ON THESE SURFACES To Add Jac...

Page 7: ...Rod Assembly 1 31 Copper Washer 3 8 Retainer Ring 1 32 Pump Core 1 9 Washer 1 33 O Ring 2 10 O Ring 1 34 PTFE Washer 1 11 Retainer Ring 1 35 Pump Core 1 12 Spring 4 36 Dust Ring 1 13 Steel Ball Stop P...

Page 8: ...ng Bypass through release valve Air cavitation in pump and or lift ram Higher capacity jack required Relief valve needs reset Lubrication flushed out of air motor requires added lubrication Adding lub...

Page 9: ...onth period Consumer Guarantee Our goods come with a guarantee that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensatio...

Reviews: