FRH300
10
1/120000&1/200000 division available
CALIBRATION
When to calibrate
Calibration may be required when it is initially installed, if the scale/balance is moved to a substantial distance. This is
necessary because the weight of a mass in one location is not necessarily the same in another location. Also, with time
and use, mechanical deviations may occur.
How to calibrate
1.
Before entering calibration mode,
there is a switch key on the bottom of the scale. Turn on the switch key first
,
press
[ON/OFF]
to turn the power on for 1minutes.
2. Enter calibration mode
Press
[ON/OFF]
to turn the power on. the display will show flash digits and then
“
--------
”
, Press
[ZERO]
, the display
will show “CAL..” , Press
[ZERO]
again ,
the display will show
“X0000
CAL
”
,
X
is flash digit. Press
[UNIT]
key the flash digit
will move to right; Press
[TARE]
key to increase the flash digit.
(X is the calibration weight which can be set according to
your requirement).
3. Calibration by the weight
When you selected the calibration weight, and then place the calibration weight on platform. Then press
[ZERO]
key
,
the
display returns to the weight value. Now the calibration is complete.
4
. Press
[ON/OFF]
, turn off the power, press
[ON/OFF]
to turn on the power again, place the weight on the platform to
make sure whether weighing is correct, if not, repeat steps 2-4.
5. Return to weighing mode
Press
[ON/OFF]
to turn the power off. Press
[ON/OFF]
again to turn on the power and the scale/balance return to the
weighing mode.