• Test each sheet individually before you install and permanently connect to power supply.
Each sheet has been tested and burnt in prior to shipping. However, shipping damage,
while unlikely is possible.
• Only connect to properly sized and correct voltage power supply as supplied with system.
MirageFlex
™
Panels are 24VDC only
.
• System must be installed by a licensed electrical contractor and installed to meet local
electrical codes. This is the customers responsibility.
• Voltage drop is always a concern when working with low voltage DC wiring. Please check
the voltage drop calculator on our website
www.tprlights.com
if you have extended run
lengths. Longer runs and improper sized wire will cause uneven brightness and may
cause failure.
•
Do not apply weight to connector blocks
. Nylon standoffs are available as an accessory for
applications where there will be a direct overlay to the MirageFlex
™
Panel. Nylon standoffs
must only be installed in marked locations.
•
Disconnect power before any cutting or modification
. Panel must be cut on cut lines only.
Cut edge must not come in contact with conductive materials. Cut edges that may come
into contact with conductive materials must be insulated/coated with silicone.
• MirageFlex
™
panels have specific areas where holes can be made in the sheet. This is the
only area where holes can be made without damaging the panel. The area is marked on the
sheet. Screw holes must be less than 1/8” and screw head size must not exceed ¼”. Pan
head screw works best. Do not over tighten. If panel starts to deform, it is too tight.
You must read and understand the following. If you have questions
call (914) 698-1141 before installing. POLARITY IS CRITICAL.