GENERAL MAINTENANCE
Housing:
The SP670 can be wiped down with a damp lint free cloth. Do not use any cleaning agents
including solvent or soap.
Battery Replacement:
When the LED indicator blinks Red the batteries need to be replaced.
1.
Turn the SP670 off. Loosen the battery cover screw and open the cover.
2.
Remove the three AAA batteries from the battery holder.
3.
Install three new AAA alkaline batteries into the holder observing correct polarity. Note:
Battery level is displayed in the Smart Probe app.
Schrader Depressor and Gasket:
The white gasket that seals the SP670 probe to a service port can
wear over time causing leaks. In addition the Schrader depressor can also wear or be damaged.
Overtightening or connection to damaged ports can also cause this.
Follow these steps to replace the Schrader depressor and/or the gasket.
1.
Using needle nose pliers, grasp the Schrader
depressor and turn valve counter clockwise.
2 Remove and replace the Schrader depressor
and/or the worn gasket.
3 Install the gasket and screw in the Schrader depressor. (New Schrader depressor and gasket are
part number A670)