H. ENTERING COMPANY AND CUSTOMER INFORMATION

1. Tap the Drop Down Menu icon to access additional features. 

2. Select “Company Info” to enter your information to show up on

the CSV file report. You can enter your company name, address,
and email.

3. Select “Customer Info” to enter the information of the customer

the tests are being performed for. You can enter the customer
name, address, and email. You can also enter the building infor-
mation in cases where the tests are being performed some-
where off-site from the customer. 

The Smart Probe App allows you to enter your company information and the customer
information who the test is being performed for. This information will be exported in the
CSV file (see page 4).

5

G. DROP DOWN MENU

1. Tap the Drop Down Menu icon to access additional features.

Main - Real Time:

Tapping this returns you to the main screen.

Select Application:

Tapping this pulls up sub applications for

variious smart probes. These include Temperature differential
(SP341), Air Volume Calulation (SP565), and Tightness Test
(SP620). Note: There are no sub applications for the SP1000.

Company Info: 

Allows you to enter your information to show up

on the CSV file report. You can enter your company name,
address, and email.

Customer Info: 

Allows you to enter the information of the cus-

tomer the tests are being performed for. You can enter the cus-
tomer name, address, and email. You can also enter the building
information in cases where the tests are being performed some-
where off-site from the customer. 

Exit:

Closes the Smart Probe App.

The Smart Probe App has a Drop Down menu allowing access to additional app features.

Summary of Contents for SP1000

Page 1: ... Advantage Visit www testproductsintl com Uses NDIR CO2 sensor for accuracy Connects to smart phone and uses the TPI Smart Probe App Perform ambient CO2 level checks Up to 6 SP1000 smart probes can connect to a single mobile device most devices 3 Year Limited Warranty ...

Page 2: ...ations 1 D Instrument Overview 2 E Taking a Measurement 3 F Additional App Features 4 G Drop Down Menu 5 H Entering Company and Customer Information 5 I Performing Ambient Air Tests 6 J Maintenance 7 K Trouble Shooting 7 L Accessories 7 M Warranty 8 N Replacing Batteries 8 ...

Page 3: ...e It connects to your mobile device and uses the TPI Smart Probe App to display temperature readings Data can be exported to a CSV file as well B SAFETY CONSIDERATIONS 1 Never attach the SP1000 to a hot surface 2 Never breath directly into the SP1000 while performing measurements Doing so will skew the actual ambient reading 3 Do not expose the unit to damp environments for extended periods of tim...

Page 4: ... the instrument off 4 Built in magnet Attach to metal surfaces for hands free operation Ensure surface is not hot 5 Serial number location Last three digits are the product identification number and marked in bold Use this num ber to distinguish between models when several SP1000 s are connected to a phone or tablet 6 Screw to open battery com partment Turn the screw counter clockwise until it is ...

Page 5: ...link to indicate a link has been established The App will display the model and ID number of the smart probe connected If the SP1000 does not auto con nect tap refresh on the App Refresh This also clears any data accumulated Displays the measured CO2 in ppm 3 Tapping the list icon allows optional functions to be accessed These include Show Hide Unit and Zeroing Sensors Show Hide Allows a device to...

Page 6: ...ny Name Test Products Intl Company Address 9615 SW Allen Blvd Customer Name Sample Customer Customer Address 1111 Sample Way Building Name Bldg 3 Building Address 2222 Sample Ave Date Time SP1000 008 ppm 5 9 2018 13 30 42 601 5 9 2018 13 30 40 599 5 9 2018 13 30 38 597 5 9 2018 13 30 36 595 5 9 2018 13 30 34 593 5 9 2018 13 30 32 590 5 9 2018 13 30 30 589 5 9 2018 13 30 28 587 4 Exported data in t...

Page 7: ... 4 5 G DROP DOWN MENU 1 Tap the Drop Down Menu icon to access additional features Main Real Time Tapping this returns you to the main screen Select Application Tapping this pulls up sub applications for variious smart probes These include Temperature differential SP341 Air Volume Calulation SP565 and Tightness Test SP620 Note There are no sub applications for the SP1000 Company Info Allows you to ...

Page 8: ...ea Take care not to breath directly into the sensor area Doing so will cause the read ings to rise and be inaccurate Another option is to leave the SP1000 in an area on a table face up or use the magnet on the back to attach it to something metal This will prevent any chance of breathing into the sensor area and skewing the readings 4 The measurement data can be exported in a CSV file for report g...

Page 9: ...on Dead or low batteries Not holding down power switch until unit turns on Defective POWER ON switch CO2 reads high all the time Make sure not to breath into the sensor during tests L ACCESSORIES Included Accessories Part Number Description A1000SP Soft pouch Optional Accessories Part Number Description A925 Carrying case for 4 smart probes A926 Carrying case for 1 or 2 smart probes Test Products ...

Page 10: ...purchase date Carefully package and return to TPI Inc TPI Canada TPI Europe Ltd 9615 SW Allen Blvd 342 Bronte Rd S Unit 6 Longley House International Drive Beaverton OR 97005 Milton Ontario L9T 5B7 Southgate Crawley USA Canada West Sussex RH10 6AQ England 503 520 9197 905 693 8558 44 0 1293 530196 www testproductsintl com www tpicanada com www tpieurope com Implied Warranties Any implied warrantie...

Page 11: ...NOTES ...

Page 12: ...w testproductsintl com Test Products International Ltd 342 Bronte Road South Unit 6 Milton Ontario Canada L9T 5B7 Tel 905 693 8558 www tpicanada com Test Products International Europe Ltd Longley House International Drive Southgate Crawley West Sussex RH10 6AQ Tel 44 0 1293 530196 www tpieurope com ...

Reviews: